Peristaltic transport of bi-viscosity fluids through a curved tube: A mathematical model for intestinal flow.

Proc Inst Mech Eng H

4 Biofluid Mechanics, Spray Research Group, School of Computing, Science & Engineering, University of Salford-Manchester, Manchester, UK.

Published: September 2016

The human intestinal tract is a long, curved tube constituting the final section of the digestive system in which nutrients and water are mostly absorbed. Motivated by the dynamics of chyme in the intestine, a mathematical model is developed to simulate the associated transport phenomena via peristaltic transport. Rheology of chyme is modelled using the Nakamura-Sawada bi-viscosity non-Newtonian formulation. The intestinal tract is considered as a curved tube geometric model. Low Reynolds number (creeping hydrodynamics) and long wavelength approximations are taken into consideration. Analytical solutions of the moving boundary value problem are derived for velocity field, pressure gradient and pressure rise. Streamline flow visualization is achieved with Mathematica symbolic software. Peristaltic pumping phenomenon and trapping of the bolus are also examined. The influence of curvature parameter, apparent viscosity coefficient (rheological parameter) and volumetric flow rate on flow characteristics is described. Validation of analytical solutions is achieved with a MAPLE17 numerical quadrature algorithm. The work is relevant to improving understanding of gastric hydrodynamics and provides a benchmark for further computational fluid dynamic simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411916658318DOI Listing

Publication Analysis

Top Keywords

curved tube
12
peristaltic transport
8
mathematical model
8
intestinal tract
8
analytical solutions
8
transport bi-viscosity
4
bi-viscosity fluids
4
fluids curved
4
tube mathematical
4
model intestinal
4

Similar Publications

Background: Photon counting detector CTs (PCD-CTs) have recently been introduced to clinical imaging. This development creates a new need for end-users to quantify and monitor the physical performance of PCDs. Traditionally, the characterization of PCD performance relied on detector counts, which are typically accessible to the manufacturer but are not usually available to clinical end-users.

View Article and Find Full Text PDF

Causing Leaf Spot on in Korea.

Plant Dis

February 2025

Korea University, Environmental Science & Ecological Engineering, Seoul, Seoul, Korea (the Republic of), 02841;

Lamium purpureum L. (purple dead-nettle), an annual herbaceous plant in the family Lamiaceae, is native to Europe and western Asia. It has become invasive in eastern Asia, including Korea and North America.

View Article and Find Full Text PDF

A 42 year old Afro-Caribbean man underwent Baerveldt Glaucoma Implant (BGI) surgery for silicone oil induced glaucoma. Three months following initial surgery, the 3-0 prolene ripcord suture was removed. Anterior segment OCT demonstrates the position of the intracameral portion of the tube before and after the 3/0 prolene stent suture (PSS) removal.

View Article and Find Full Text PDF

Construction of Double-layered DNA Tiles and Arrays from Double Crossover Motifs.

Chembiochem

February 2025

State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Nanjing University, 163 Xianlin Avenue, Nanjing, 210023, P. R. China E-amil.

DNA double crossover (DX) motifs including DAE (double crossover, antiparallel, even spacing) and DAO (double crossover, antiparallel, odd spacing) are well-known monolayered DNA building blocks for construction of 2D DNA arrays and tubes in nanoscale and microscale. Compared to the 3D architectures of DNA origami and single-stranded DNA bricks to build nanoscale 3D bundles, tessellations, gears, castles, etc., designs of double- and multi-layers of DX motifs for 3D architectures are still limited.

View Article and Find Full Text PDF

In this study we evaluated the effects of flow lamination on aerosol flow dynamics and deposition at the exit point in testing models with spatial barriers (narrowing or curving).We compared ModiFlow (MF) to an idealized Standard Spacer (SS) in their efficiency of delivery of aerosolized medication (fluticasone) across different types of spatial barriers. Fluticasone propionate HFA Inhaler from Prasco Labs 220 µg per actuation was used to deliver 1 spray in each test tube.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!