The evolution of deep learning techniques has been transformative as they have allowed complex mappings to be trained between control inputs and outputs without the need for feature engineering. In this work, a myoelectric control system based on convolutional neural networks (CNN) is proposed as a possible alternative to traditional approaches that rely on specifically designed features. This CNN-based system is validated using a real-time Fitts' law style target acquisition test requiring single and combined wrist motions. The performance of the proposed system is then compared to that of a standard support vector machine (SVM) based myoelectric system using a set of time-domain features. Despite the prevalence and demonstrated performance of these well-known features, no significant difference (p>0.05) was found between the two methods for any of the computed control metrics. This demonstrates the potential for automated learning approaches to extract complex and rich information from stochastic biological signals. This first evaluation of the usability of a CNN in a real-time myoelectric control environment provides a basis for further exploration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6136764 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0203835 | PLOS |
Diagnostics (Basel)
December 2024
Exero Medical Ltd., Or Yehuda 6037606, Israel.
Anastomotic leakage (AL) is one of the most devastating complications after colorectal surgery. The verification of the adequate perfusion of the anastomosis is essential to ensuring anastomosis integrity following colonic resections. This study aimed to evaluate the efficacy of measuring the electrical activity of the colonic muscularis externa at an anastomosis site for perfusion analysis following colorectal surgery.
View Article and Find Full Text PDFJ Neural Eng
January 2025
Electrical and Computer Engineering Department, University of New Brunswick, 3 Bailey Dr., Fredericton, New Brunswick, E3B5A3, CANADA.
Objective: While myoelectric control has been commercialized in prosthetics for decades, its adoption for more general human-machine interaction has been slow. Although high accuracies can be achieved across many gestures, current control approaches are prone to false activations in real-world conditions. This is because the same electromyogram (EMG) signals generated during the elicitation of gestures are also naturally activated when performing activities of daily living (ADLs), such as when driving to work or while typing on a keyboard.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
EMG feedback improves force control of a myoelectric hand prosthesis by conveying the magnitude of the myoelectric signal back to the users via tactile stimulation. The present study aimed to test if this method can be used by a participant with a high-level amputation, and whose muscle used for prosthesis control (pectoralis major) was not intuitively related to hand function. Vibrotactile feedback was delivered to the participant's torso, while the control was tested using EMG from three different muscles.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
School of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China.
Surface electromyography (sEMG) signals reflect the local electrical activity of muscle fibers and the synergistic action of the overall muscle group, making them useful for gesture control of myoelectric manipulators. In recent years, deep learning methods have increasingly been applied to sEMG gesture recognition due to their powerful automatic feature extraction capabilities. sEMG signals contain rich local details and global patterns, but single-scale convolutional networks are limited in their ability to capture both comprehensively, which restricts model performance.
View Article and Find Full Text PDFJ Neuroeng Rehabil
December 2024
Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, USA.
Background: This research aims to improve the control of assistive devices for individuals with hemiparesis after stroke by providing intuitive and proportional motor control. Stroke is the leading cause of disability in the United States, with 80% of stroke-related disability coming in the form of hemiparesis, presented as weakness or paresis on half of the body. Current assistive exoskeletonscontrolled via electromyography do not allow for fine force regulation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!