A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dosimetric assessment of tumor control probability in intensity and volumetric modulated radiotherapy plans. | LitMetric

Objective:: Radiobiological models have been used to calculate the outcomes of treatment plans based on dose-volume relationship. This study examines several radiobiological models for the calculation of tumor control probability (TCP) of intensity modulated radiotherapy plans for the treatment of lung, prostate, and head and neck (H&N) cancers.

Methods:: Dose volume histogram (DVH) data from the intensity modulated radiotherapy plans of 36 lung, 26 prostate, and 87  H&N cases were evaluated. The Poisson, Niemierko, and Marsden models were used to calculate the TCP of each disease group treatment plan. The calculated results were analyzed for correlation and discrepancy among the three models, as well as different treatment sites under study.

Results:: The median value of calculated TCP in lung plans was 61.9% (34.1-76.5%), 59.5% (33.5-73.9%) and 32.5% (0.0-93.9%) with the Poisson, Niemierko, and Marsden models, respectively. The median value of calculated TCP in prostate plans was 85.1% (56.4-90.9%), 81.2% (56.1-88.7%) and 62.5% (28.2-75.9%) with the Poisson, Niemierko, and Marsden models, respectively. The median value of calculated TCP in H&N plans was 94.0% (44.0-97.8%) and 94.3% (0.0-97.8%) with the Poisson and Niemierko models, respectively. There were significant differences between the calculated TCPs with the Marsden model in comparison with either the Poisson or Niemierko model (p < 0.001) for both lung and prostate plans. The TCPs calculated by the Poisson and Niemierko models were significantly correlated for all three tumor sites.

Conclusion:: There are variations with different radiobiological models. Understanding of the correlation and limitation of a TCP model with dosimetric parameters can help develop the meaningful objective functions for plan optimization, which would lead to the implementation of outcome-based planning. More clinical data are needed to refine and consolidate the model for accuracy and robustness.

Advances In Knowledge:: This study has tested three radiobiological models with varied disease sites. It is significant to compare different models with the same data set for better understanding of their clinical applicability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404826PMC
http://dx.doi.org/10.1259/bjr.20180471DOI Listing

Publication Analysis

Top Keywords

poisson niemierko
24
radiobiological models
16
modulated radiotherapy
12
radiotherapy plans
12
lung prostate
12
niemierko marsden
12
marsden models
12
median calculated
12
calculated tcp
12
models
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!