Background: Propofol is one of the most widely used injectable anaesthetic agents in veterinary practice. Cardiovascular effects related to propofol use in dogs remain less well defined. The main objective of this study was to evaluate the haemodynamic changes during induction of general anaesthesia with propofol in healthy dogs, by a beat-to-beat continuous monitoring. All dogs were premedicated with intramuscular acepromazine (0.015 mg/kg) and methadone (0.15 mg/kg). Transthoracic echocardiography was used to measure the velocity time integral (VTI) of the left ventricular outflow tract. A syringe driver, programmed to deliver propofol 5 mg/kg over 30 s followed by a continuous infusion of 25 mg/kg/h, was used to induce and maintain anaesthesia. From the initiation of propofol administration, heart rate (HR) and mean invasive arterial blood pressure (MAP) were recorded every 5 s for 300 s, while aortic blood flow was continuously recorded and stored for 300 S. maximum cardiovascular depression was defined the lowest MAP (MAP_Tpeak) recorded during the monitored interval. VTI and VTI*HR were calculated at 0, 30, 90, 120, 150 and 300 s post administration of propofol, and at MAP_Tpeak. Haemodynamic effects of propofol in relation to plasma and biophase concentrations were also evaluated by pharmacokinetics simulation.
Results: The median (range) HR was significantly higher (p = 0.006) at the moment of maximum hemodynamic depression (Tpeak) [105(70-148) bpm] compared with pre-induction values (T0) [65(50-120) bpm]. The median (range) MAP was significantly lower (p < 0.001) at Tpeak [61(51-69) mmHg] compared with T0 [88(72-97) mmHg]. The median (range) VTI and VTI*HR were similar at the two time points [11.9(8.1-17.3) vs 13,3(9,4-16,5) cm, and 1172(806-1554) vs 1002(630-1159) cm*bpm, respectively].
Conclusions: Induction of anaesthesia with propofol causes a drop of arterial pressure in healthy dogs, however cardiac output is well maintained by compensatory chronotropic response. The magnitude of MAP_Tpeak may be strictly related with propofol plasma concentration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6134702 | PMC |
http://dx.doi.org/10.1186/s12917-018-1608-8 | DOI Listing |
Sensors (Basel)
January 2025
Department of Psychological and Cognitive Sciences, Tsinghua University, Beijing 100084, China.
The objective identification of depression using physiological data has emerged as a significant research focus within the field of psychiatry. The advancement of wearable physiological measurement devices has opened new avenues for the identification of individuals with depression in everyday-life contexts. Compared to other objective measurement methods, wearables offer the potential for continuous, unobtrusive monitoring, which can capture subtle physiological changes indicative of depressive states.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Faculty of Sport and Health Sciences, University of Jyväskylä, 40014 Jyväskylä, Finland.
Previous studies on the effects of intensified training on sleep quality/quantity have been somewhat contradictory. Moreover, recreational athletes often track various sleep metrics, and those metrics' actual connections to training adaptations are unknown. This study explored the effects of intensified training on sleep and nightly recovery along with their associations with training adaptations.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Sciences, Xi'an Technological University, Xi'an 710021, China.
A solution to address the issues of environmental light interference in Remote Photoplethysmography (rPPG) methods is proposed in this paper. First, signals from the face's region of interest (ROI) and background noise signals are simultaneously collected, and the two signals are processed by a differential to obtain a more accurate rPPG signal. This method effectively suppresses background noise and enhances signal quality.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical Engineering, American University of Sharjah, Sharjah 26666, United Arab Emirates.
Accurately identifying and discriminating between different brain states is a major emphasis of functional brain imaging research. Various machine learning techniques play an important role in this regard. However, when working with a small number of study participants, the lack of sufficient data and achieving meaningful classification results remain a challenge.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal.
Invisible health monitoring is currently a topic of global interest within the scientific community. Sensorization of everyday objects can provide valuable health information without requiring any changes in people's routines. In this work, a feasibility study of photoplethysmography (PPG) acquisition in the lower limbs for continuous and real-time monitoring of the vital signs, including heart rate (HR) and respiratory rate (RR), is presented.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!