Intrauterine Device Expulsion After Postpartum Placement: A Systematic Review and Meta-analysis.

Obstet Gynecol

Division of Reproductive Health, Centers for Disease Control and Prevention, Atlanta, Georgia; the University of North Carolina at Chapel Hill, Chapel Hill, North Carolina; and Emory University School of Medicine, Atlanta, Georgia.

Published: October 2018

Objective: To estimate expulsion rates among women with postpartum intrauterine device (IUD) placement by timing of insertion, IUD type, and delivery method.

Data Sources: We searched PubMed, Cochrane Library, and ClinicalTrials.gov from 1974 to May 2018.

Methods Of Study Selection: We searched databases for any published studies that examined postpartum placement of a copper IUD or levonorgestrel intrauterine system and reported counts of expulsions. We assessed study quality using the U.S. Preventive Services Task Force evidence grading system. We calculated pooled absolute rates of IUD expulsion and estimated adjusted relative risks (RRs) for timing of postpartum placement, delivery method, and IUD type using log-binomial multivariable regression model.

Tabulation, Integration, And Results: We identified 48 level I to II-3 studies of poor to good quality. Pooled rates of expulsion varied by timing of IUD placement, ranging from 1.9% with interval placements (4 weeks postpartum or greater), 10.0% for immediate placements (10 minutes or less after placental delivery), and 29.7% for early placements (greater than 10 minutes to less than 4 weeks postpartum). Immediate and early postpartum placements were associated with increased risk of expulsion compared with interval placement (adjusted RR 7.63, 95% CI 4.31-13.51; adjusted RR 6.17, 95% CI 3.19-11.93, respectively). Postpartum placement less than 4 weeks after vaginal delivery was associated with an increased risk of expulsion compared with cesarean delivery (adjusted RR 5.19, 95% CI 3.85-6.99). Analysis of expulsion rates at less than 4 weeks postpartum also indicated that the levonorgestrel intrauterine system was associated with a higher risk of expulsion (adjusted RR 1.91, 95% CI 1.50-2.43) compared with CuT380A.

Conclusion: Postpartum IUD expulsion rates vary by timing of placement, delivery method, and IUD type. These results can aid in counseling women to make an informed choice about when to initiate their IUD and to help institutions implement postpartum contraception programs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6549490PMC
http://dx.doi.org/10.1097/AOG.0000000000002822DOI Listing

Publication Analysis

Top Keywords

postpartum placement
16
expulsion rates
12
iud type
12
weeks postpartum
12
risk expulsion
12
postpartum
11
expulsion
9
iud
9
intrauterine device
8
placement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!