A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Resonance light scattering sensor of the metal complex nanoparticles using diethyl dithiocarbamate doped graphene quantum dots for highly Pb(II)-sensitive detection in water sample. | LitMetric

Resonance light scattering sensor of the metal complex nanoparticles using diethyl dithiocarbamate doped graphene quantum dots for highly Pb(II)-sensitive detection in water sample.

Spectrochim Acta A Mol Biomol Spectrosc

Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen 40002, Thailand. Electronic address:

Published: January 2019

This study was aimed to detect Pb using diethyl dithiocarbamate-doped graphene quantum dots (DDTC-GQDs) based pyrolysis of citric acid. The excitation maximum wavelength (λ ex = 337 nm) of the DDTC-GQDs solution was blue shift from bare GQDs (λ ex = 365 nm), with the same emission maximum wavelength (λ em = 459 nm) indicating differences in the desired N, S matrices decorating in the nanoparticles. Their resonance light scattering intensities were peaked at the same λ, ex/em = 551/553 nm without any background effect of both ionic strength and masking agent. Under optimal conditions, the linear range was 1.0-10.0 μg L (R = 0.9899), limit of detection was 0.8 μg L and limit of quantification was 1.5 μg L. The precision, expressed as the relative standard deviations, for intra-day and inter-day analyses was 0.87% and 4.47%, respectively. The recovery study of Pb for real water samples was ranged between 80.8% and 109.5%. The proposed method was also proved with certified water sample containing 60 μg L Pb giving an excellent accuracy and was then implied satisfactorily for ultra-trace determination of Pb in drinking water and tap water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2018.09.002DOI Listing

Publication Analysis

Top Keywords

resonance light
8
light scattering
8
graphene quantum
8
quantum dots
8
water sample
8
maximum wavelength
8
water samples
8
water
5
scattering sensor
4
sensor metal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!