Purpose: To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model.
Materials And Methods: Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform:methanol, analyzed in a beta counter, and μg/lens of cholesterol was determined.
Results: Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93±0.02 μg/lens; 0.95±0.01 μg/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37±0.03 μg/lens; 0.47±0.12 μg/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05).
Conclusion: Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICL.0000000000000547 | DOI Listing |
Adv Mater
December 2024
Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure and Hubei Engineering Research Center for Biomaterials and Medical Protective Materials, Huazhong University of Science and Technology, Wuhan, 430074, P. R. China.
The development of zero-power moisture-harvesting technology in an unsaturated atmosphere is of great significance for coping with global freshwater scarcity. Here, inspired by Pachydactylus rangei's (Namib sand gecko) ability to evade thermal radiation and harvest moisture, a power-free cooling moisture harvester (PFCMH) is fabricated using the continuous, industrialized micro-extrusion compression molding. A Luneburg lens is introduced in the PFCMH for the first time, endowing it with a high reflectivity of ≈92.
View Article and Find Full Text PDFCureus
November 2024
Ophthalmology, Moorfields Eye Hospital, London, GBR.
We report a case of spontaneous total iris avulsion that occurred during corneal wound hydration following an uneventful phacoemulsification procedure. An 86-year-old woman underwent cataract surgery on her right eye, during which a single-piece acrylic intraocular lens (Bausch and Lomb Akreos Adapt Advanced Optics, Bausch and Lomb Incorporated, Rochester, NY, USA) was implanted in the bag, and the viscoelastic material was removed. During corneal wound hydration, total iris avulsion was observed, with the iris prolapsing out of the anterior chamber through the main wound.
View Article and Find Full Text PDFCureus
November 2024
Ophthalmology, District General Hospital Trincomalee, Trincomalee, LKA.
Introduction The Sri Lankan economic crisis that began in 2019 led to the suspension of cataract services in many districts. Although humanitarian missions were quick to supply materials, there was a lack of scientific evidence to predict the required intraocular lens power for patients with cataracts. This study aimed to assess the average lens power among patients from Trincomalee district, Sri Lanka, based on sex and age groups.
View Article and Find Full Text PDFBMC Womens Health
December 2024
Health Management Center, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Medical University, Chongqing, 400010, China.
Background: Age-related cataract (ARC) is among the most common blinding eye disorders among the elderly. Prenatal nutrition may cause irreversible damage to the development of the ocular crystalline lens. Nevertheless, the potential association between prenatal malnutrition and age-related cataract has not been thoroughly examined.
View Article and Find Full Text PDFSci Rep
December 2024
Computer Engineering Department, Lorestan University, Khorramabad, Iran.
This paper presents a slot antenna integrated with a split ring resonator (SRR) and feed line, designed to achieve a high Q-factor while maximizing channel capacity utilization. By incorporating a lens into the dielectric resonator antenna (DRA), we enhance both bandwidth and directivity, with the dielectric material's permittivity serving as a key control parameter for radiation characteristics. We explore water and ethanol as controllable dielectrics within the terahertz (THz) frequency range (0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!