A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Research on the Distribution of Gas Concentration of Two-Dimensional Reconstruction Based on Tunable Diode Laser Absorption Spectroscopy with Multispectral Absorption]. | LitMetric

The two-dimensional concentration distribution was reconstructed by using algebraic iterative reconstruction algorithm. This paper mainly focused on the effects of multispectral H2O absorptions on condition that the laser beam was less and the temperature was known, i.e. the influence of temperature on spectral line-strength was not considered as to this concentration distribution. Based on ART algorithm, increased spectral lines and increased laser beam were compared under the same concentration model. Three H2O lines were selected to reconstruct two-dimensional distribution of non-uniform gas concentration, and these three transitions were selected within the external cavity diode laser turning range in the simulated system. The interested region was discretized to 10×10 grid points, and the temperature and concentration of the reconstruction model were not evenly distributed, so the unimodal distribution and bimodal distribution were used to describe the concentration distribution. The simulated system also calculated the effective utilization of laser beams and absorption lines. The results showed that the reconstruction quality quickly increased with increasing H2O absorption lines when the laser beams were very few, the increased absorption lines could get more spectral information related to the concentration. The increased laser beam is also effective to improve the accuracy of reconstruction results, but increasing the absorption lines can better reconstruct a two-dimensional concentration distribution. Improving the absorption lines can also effectively reduce the costs of the hardware and the complexity of the measurement system, which shows that the multispectral absorption lines are applicable to in-situ measurements.

Download full-text PDF

Source

Publication Analysis

Top Keywords

absorption lines
24
concentration distribution
16
laser beam
12
concentration
9
gas concentration
8
diode laser
8
two-dimensional concentration
8
lines
8
increased laser
8
reconstruct two-dimensional
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!