In total hip arthroplasty (THA), it is generally accepted that the bones of the acetabular cup and femur of hip joint must be accurately cut and components (artificial joint parts) be implanted in exact positions at exact angles to achieve improvement of daily living (ADL) and quality of life (QOL). However, with the conventional surgical method, it is difficult to grasp and measure the acetabular cup and femoral stem precisely during surgery, making some kind of reliable guide necessary. Although it was reported that an accurate angle was achieved in acetabular cup implantation by support instruments for surgical planning, an effective support instrument is now being developed for stem implantation on the out-of-reach femur side. This is the first clinical study to assess the efficacy and safety of anterolateral approach THA using an extracorporeal patient-specific femoral guide (PSG) for stem implantation with three-dimensional (3D) surgical support software in patients with hip joint disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2739/kurumemedj.MS652002 | DOI Listing |
Several studies suggested that total hip arthroplasty (THA) was more technical demanding following previous pelvic osteotomy (PO), resulting in poor outcomes compared with primary THA. However, the other studies regarding this topic had reported contradictory results. Therefore, we conducted this meta-analysis to compare the clinical results and other parameters between total hip arthroplasty following pelvic osteotomy and primary total hip arthroplasty.
View Article and Find Full Text PDFLarge-diameter heads (LDHs) in total hip arthroplasty (THA) enhance range of motion but require thinner liners. Monoblock acetabular components with ceramic liners could reduce liner fracture risks during modular acetabular component assembly. This study aims to confirm the safety and clinical performance of the monoblock Maxera Cup in THA.
View Article and Find Full Text PDFArthroplast Today
February 2025
Department of Orthopaedic Surgery, University of California, San Diego, San Diego, CA, USA.
Management of periacetabular osteolysis is a challenging dilemma in revision total hip arthroplasty. When the acetabular shell is well-fixed, the surgeon may prefer to retain the cup to minimize further bone loss. However, filling the surrounding defect can be difficult if the area of involvement is massive.
View Article and Find Full Text PDFZhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Artificial Joint Revision, Luoyang Orthopedic-Traumatological Hospital of Henan Province (Henan Provincial Orthopedic Hospital), Zhengzhou Henan, 450003, P. R. China.
Objective: To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Methods: A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.
J Arthroplasty
January 2025
Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana; Indiana Joint Replacement Institute, Indianapolis, Indiana. Electronic address:
Background: Use of jumbo femoral heads (≥ 40 mm) in total hip arthroplasty (THA) decreases postoperative dislocation, however, may leave patients more susceptible to groin pain. Limited data exist for the effect of jumbo femoral heads and acetabular cup position on modern patient-reported outcome measures (PROMs). This study evaluated the effect of jumbo femoral heads and acetabular cup position on PROMs after primary THA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!