A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemical immunoassay for lactalbumin based on the use of ferrocene-modified gold nanoparticles and lysozyme-modified magnetic beads. | LitMetric

Electrochemical immunoassay for lactalbumin based on the use of ferrocene-modified gold nanoparticles and lysozyme-modified magnetic beads.

Mikrochim Acta

Faculty of Sciences of Tunis, Laboratory of Analytical Chemistry and Electrochemistry (LR99ES15), Sensors and Biosensors Group, University of Tunis El Manar, Campus Universitaire de Tunis El Manar, Tunis El Manar, 2092, Tunis, Tunisia.

Published: September 2018

The authors describe a method for electrochemical determination of the breast cancer biomarker α-lactalbumin (α-LA) using disposable screen-printed carbon electrodes (SPCEs). Lysozyme-conjugated FeO nanoparticles (Lys-FeONPs) were used to capture α-LA on the surface of the SPCEs which then is trapped in an immunosandwich using secondary antibodies labeled with ferrocene-modified gold nanoparticles. The amperometric response of ferrocene (recorded at +0.1 V vs. silver pseudo-reference electrode) as well as the electrocatalytic activity of gold nanoparticles on the hydrogen evolution reaction (recorded at -1.0 V Vs Ag pseudo-reference electrode) was exploited to sense α-LA. A sensitive voltammetric response is observed, with (a) a sensitivity of 0.8789 μA·nM.cm, (b) a detection limit (LOD, at S/N = 3) as low as 0.07 ng·mL, and (c) linear response in the 0.75 to 630 ng mL α-LA concentration range. The assay is selective and reproducible, and the SPCEs have good storage stability. The SPCEs were applied (a) to the analysis of (spiked) maternal milk, (b) of spiked serum from healthy and pregnant persons, and (c) of serum of patients suffering from breast cancer. Graphical abstract Schematic presentation of a sensitive electrochemical immunoassay platform based on ferrocene modified gold nanoparticles and lysozyme modified magnetic beads for the determination of alpha lactalbumin in human sera and breast milk by the amperometric response of ferrocene and hydrogen evolution reaction.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-018-2986-0DOI Listing

Publication Analysis

Top Keywords

gold nanoparticles
16
electrochemical immunoassay
8
ferrocene-modified gold
8
magnetic beads
8
breast cancer
8
amperometric response
8
response ferrocene
8
pseudo-reference electrode
8
hydrogen evolution
8
evolution reaction
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!