Orbital implants are commonly used to repair orbital blowout fractures, to restore the functional and anatomical structure of the orbit. Porous polyethylene implants are a type of alloplastic implant and are widely used for orbital reconstruction as micropores facilitate the growth of fibers and blood vessels through the material. Rare complications associated with porous polyethylene implants used to treat blowout fractures include delayed orbital inflammation and osteomyelitis. The authors describe a 68-year-old man who presented with a 5-year delayed porous polyethylene implant infection and cicatricial ectropion with osteomyelitis after an orbital blowout fracture repair. The patient underwent surgery to incision and drainage of orbital abscess with ectropion correction surgery. He was treated with intravenous antibiotics for 6 weeks due to osteomyelitis and made a good recovery.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000004985DOI Listing

Publication Analysis

Top Keywords

porous polyethylene
16
polyethylene implant
8
orbital
8
delayed orbital
8
osteomyelitis orbital
8
orbital reconstruction
8
orbital blowout
8
blowout fractures
8
polyethylene implants
8
porous
4

Similar Publications

The application of antimicrobial surfaces requires proof of their effectivity by methods in laboratories. One of the most common test methods is ISO 22196:2011, which represents a simple and inexpensive protocol by applying the bacterial suspension with known volume and concentration covered under a polyethylene film on the surfaces. The incubation is then conducted under defined humidity conditions for 24 h.

View Article and Find Full Text PDF

A lubcan cross-linked polyethylene glycol dimethyl ether hydrogel for hyaluronic acid replacement as soft tissue engineering fillers.

Int J Biol Macromol

January 2025

Center for Molecular Metabolism, Nanjing University of Science & Technology, Nanjing 210094, China; Key Laboratory of Metabolic Engineering and Biosynthesis Technology, Ministry of Industry and Information Technology, 210094, China. Electronic address:

The structure of soft tissues is often destroyed by injury and aging. Injectable fillers eliminate the need for surgery and enhance repair. Hyaluronic acid-based hydrogels are commonly employed for their effectiveness and biocompatibility.

View Article and Find Full Text PDF

Exploring diverse biomaterials and implants in the ear, nose, and throat by understanding adverse effects and post-usage events. Literature was obtained from Scopus, PubMed, Google Scholar, and Web of Science. A comprehensive analysis was conducted on original research studies, case reports, and case series spanning from December 2010 to May 2022.

View Article and Find Full Text PDF

Expanding access to maggot containment dressings through redesign and innovation.

Int Wound J

January 2025

Applied BioSciences, Faculty of Science and Engineering, Macquarie University, North Ryde, New South Wales, Australia.

There are two major styles of maggot debridement dressings: (1) confinement dressings that form a cage around the wound, and (2) containment dressings that completely surround the maggots within a sealed porous bag. For producers and clinicians wanting to prepare containment dressings using readily available polyester bags, it is currently difficult to seal these bags without expensive high-temperature plastic welders. This study aimed to identify simple and affordable methods for sealing maggots within polyester net bags.

View Article and Find Full Text PDF

Microporous carbon derived from waste plastics for efficient adsorption of tetracycline: Adsorption mechanism and application potentials.

Environ Res

January 2025

MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage, School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, 150001, China.

In recent years, the accumulation of waste plastics and emergence plastic-derived pollutants such as microplastics have driven significantly the development and updating of waste plastic utilization technology. This study prepared the porous carbon (PC-1-KOH) material directly from polyethylene terephthalate (PET) in waste plastic bottles using KOH activation and molten salt strategy for efficient removal of antibiotic tetracycline (TC). The maximum removal efficiency of TC was 100.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!