Time base evaluation for atom gravimeters.

Rev Sci Instrum

MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China.

Published: August 2018

Time is an inevitable quantity involved in absolute gravity measurements, and 10 MHz frequency standards are usually utilized as time base. Here we investigate the influence of time base bias on atom-interferometry-based gravity measurements and present an onsite calibration of the time base bias relying on an atom gravimeter itself. With a microwave source referenced to the time base, the time base bias leads to a magnified frequency shift of the microwave source output. The shift is then detected by Ramsey spectroscopy with the clock transition of Rb atoms as a frequency discriminator. Taking advantage of available free-fall cold atoms and developed techniques of measuring the atom energy level shift in atom gravimeters, the calibration achieves an accuracy of 0.6 mHz for the time base. And the corresponding error for gravity measurements is constrained to 0.1 Gal, meeting the requirement of state-of-the-art gravimeters. The presented evaluation is important for the applications of atom gravimeters.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5039653DOI Listing

Publication Analysis

Top Keywords

time base
28
atom gravimeters
12
gravity measurements
12
base bias
12
time
8
microwave source
8
base
6
atom
5
base evaluation
4
evaluation atom
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!