Background: We assess the potency of different Doppler indices in the differentiation of obstructive and nonobstructive hydronephrosis.
Materials And Methods: In this study, infants and children who were referred for the evaluation of unilateral hydronephrosis were enrolled. Ultrasonography for the assessment of the degree of hydronephrosis and a voiding cystourethrogram for the exclusion of vesicoureteral reflux was performed. Then, Doppler ultrasonography was done for both kidneys of each patient using four classic Doppler indices as well as the difference (delta) of each index between to kidneys. Diuretic renography with 99 mTc-ethylene dicysteine (99 mTc-EC) was performed for each patient.
Results: Thirty-nine patients met the inclusion criteria. After diuretic renography, 29 (74.35%) patients had shown a nonobstructive pattern, and ten (25.65%) patients had a partial (intermediate) or complete obstruction. Using receiver operating characteristic (ROC) curve, none of the classic indices of Doppler duplex (i.e., resistive index [RI], resistance index, end diastolic velocity, and peak systolic velocity) had the ability to make a difference between obstructive and nonobstructive hydronephrosis. However, by calculating the difference (delta) of these indices between two kidneys of each patient, delta RI could differentiate the nonobstructive condition, significantly ( = 0.006). A cutoff value of 0.055 has 60% sensitivity and 82.8% specificity. The area under the ROC curve for delta RI is 0.795 (standard error: 0.086, 95% confidence interval [CI]: 0.626, 0.964). Furthermore, RI ratio between two kidneys of each patient could differentiate the nonobstructive condition, significantly ( = 0.012). A cutoff point of 1.075 has 70% sensitivity and 82.8% specificity. The area under the ROC curve for RI ratio was 0.769 (standard error: 0.104, 95% CI: 0.565, 0.973).
Conclusion: This study shows that RI ratio and delta RI with a high specificity could differentiate nonobstructive hydronephrosis and therefore it is a promising way to use especially in the follow-up of children with hydronephrosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6116660 | PMC |
http://dx.doi.org/10.4103/jrms.JRMS_627_17 | DOI Listing |
Clin Transl Gastroenterol
January 2025
Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China.
Background: Gastrointestinal ultrasound (GIUS) is recommended for monitoring Crohn's disease (CD). GIUS scores are used to quantify CD activity. Among them, IBUS-SAS (International Bowel Ultrasound Segmental Activity Score), BUSS (Bowel Ultrasound Score), Simple-US (Simple Ultrasound Score), and SUS-CD (Simple Ultrasound Score for Crohn's Disease) are most commonly used.
View Article and Find Full Text PDFEur J Case Rep Intern Med
December 2024
Radiology Department, Seychelles Hospital, Healthcare Agency, Victoria, Seychelles.
Unlabelled: Upper extremity deep vein thrombosis (UEDVT) is relatively rare, and much less as an initial presentation of systemic lupus erythematosus (SLE). Primary UEDVT should be considered in individuals with unilateral arm swelling where the brachial, axillary, and subclavian veins are frequently involved. SLE is a chronic autoimmune disease that predominantly affects women of childbearing age and of African descent.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Christian Doppler Laboratory for Innovative Gut Health Concepts of Livestock, Austria; BOKU University, Vienna, Dept. IFA-Tulln, Institute of Bioanalytics and Agro-Metabolomics, Tulln, Austria.
Background: Untargeted metabolomics requires robust and reliable strategies for data processing to extract relevant information form the underlying raw data. Multiple platforms for data processing are available, but the choice of software tool can have an impact on the analysis. This study provides a comprehensive evaluation of four workflows based on commonly used metabolomics software tools: XCMS, Compound Discoverer, MS-DIAL, and MZmine.
View Article and Find Full Text PDFAm J Obstet Gynecol
January 2025
Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, United Kingdom; Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute, St George's University of London, London, United Kingdom; Twin and Multiple Pregnancy Centre for Research and Clinical Excellence, St George's University Hospital, St George's University of London, London, UK; Fetal Medicine Unit, Liverpool Women's Hospital, Liverpool, United Kingdom. Electronic address:
Objective: The objective of this study was to conduct a longitudinal assessment of inter-twin growth and Doppler discordance, to identify possible distinct patterns, and to investigate the predictive value of longitudinal discordance patterns for adverse perinatal outcomes in twin pregnancies.
Methods: This retrospective cohort study included twin pregnancies followed and delivered at a tertiary University Hospital in London (UK), between 2010 and 2023. We included pregnancies with at least three ultrasound assessments after 18 weeks and delivery after 34 weeks' gestation.
Objective: To assess the agreement of transpulmonary thermodilution (TPTD) and transpulmonary ultrasound dilution (TPUD) against direct measurement of main pulmonary artery flow with an ultrasound transit time flow probe (UTF) over a wide range of conditions in anesthetized cats. Additionally, the trending ability of TPTD, TPUD, and esophageal Doppler ultrasonography (EDU) was evaluated against UTF.
Methods: 12 purpose-bred cats were used.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!