Improved directional hearing of children with congenital unilateral conductive hearing loss implanted with an active bone-conduction implant or an active middle ear implant.

Hear Res

Department of Biophysics, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen, Nijmegen, The Netherlands; Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre Nijmegen, Nijmegen, The Netherlands.

Published: December 2018

AI Article Synopsis

Article Abstract

Different amplification options are available for listeners with congenital unilateral conductive hearing loss (UCHL). For example, bone-conduction devices (BCDs) and middle ear implants. The present study investigated whether intervention with an active BCD, the Bonebridge, or a middle ear implant, the Vibrant Soundbridge (VSB), affected sound-localization performance of listeners with congenital UCHL. Listening with a Bonebridge or VSB might provide access to binaural cues. However, when fitted with the Bonebridge, but not with a VSB, binaural processing might be affected through cross stimulation of the contralateral normal hearing ear, and could interfere with processing of binaural cues. In the present study twenty-three listeners with congenital UCHL were included. To assess processing of binaural cues, we investigated localization abilities of broadband (BB, 0.5-20 kHz) filtered noise presented at varying sound levels. Sound localization abilities were analyzed separately for stimuli presented at the side of the normal-hearing ear, and for stimuli presented at the side of the hearing-impaired ear. Twenty-six normal hearing children and young adults were tested as control listeners. Sound localization abilities were measured under open-loop conditions by recording head-movement responses. We demonstrate improved sound localization abilities of children with congenital UCHL, when listening with a Bonebridge or VSB, predominantly for stimuli presented at the impaired (aided) side. Our results suggest that the improvement is not related to accurate processing of binaural cues. When listening with the Bonebridge, despite cross stimulation of the contralateral cochlea, localization performance was not deteriorated compared to listening with a VSB.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6863747PMC
http://dx.doi.org/10.1016/j.heares.2018.08.006DOI Listing

Publication Analysis

Top Keywords

binaural cues
16
localization abilities
16
middle ear
12
listeners congenital
12
congenital uchl
12
listening bonebridge
12
bonebridge vsb
12
processing binaural
12
sound localization
12
stimuli presented
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!