Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of the study is to investigate whether the Doppler indexes which measured at different points of the umbilical cord (UC) are related to the cord length. In this prospective study, umbilical artery (UA) Doppler indexes were measured at the fetal and placental insertion, free loop (FL) and intra-abdominal (IA) portion at 37-42 weeks of gestation in low-risk singleton pregnancies. After birth, the UC was measured. The difference of Doppler indexes of different points was evaluated by nonparametric Kruskal-Wallis test or analysis of variance (ANOVA) test and significant values have been adjusted by the Bonferroni correction for multiply tests. The correlation of between UC length and change of Doppler indexes which measured at different points of the UC was evaluated using Spearman's rank correlation test. The data of 74 participants were analyzed in this study. Mean UC length was 58 cm (min: 38 cm and max: 84 cm). There was no difference between characteristics of two groups that UC length <58 cm and ≥58 cm and different percentiles. UA systole/diastole (S/D) rate, resistance index (RI), and pulsatility index (PI) were higher at the IA portion than other measurement points ( = .003, <.001, and <.001, respectively). The mean differences (delta values) of UA blood velocity between the fetal and placental ends (PEs) were correlated UC length ( = 0.32, = .04). The differences of UA blood velocities between the fetal and PEs may be a useful marker for UC length prediction during antenatal period.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/14767058.2018.1506440 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!