Lutein and zeaxanthin exhibit significant biological activities therefore their dietary intake through carotenoid-rich foods and supplements is strongly recommended as preventive approach. Hence their extraction from natural substrates targets to their commercial exploitation as nutraceuticals and ocular pharmaceuticals. Since carotenoids' bioavailability is higher in fat-containing substrates, egg yolk is considered an ideal food matrix. DOE-based optimization of novel high energy extraction practices achieves efficient recovery of xanthophylls from lipid sources. In this research, 2 full factorial and Box-Behnken designs (BBD) were applied for optimizing ultrasound- (UAE) and microwave-assisted extraction (MAE) variables (i.e. extraction solvent, temperature, time, US or MW power and solvent/material ratio). LC-MS/MS results pointed out the precedence of UAE in lutein and zeaxanthin extraction, where higher yields were obtained with 1:1 n-hexane-acetone as solvent mixture at 19 min, 600 W and 35 mL g. UAE carotenoid content was higher than MAE due to the different mechanisms laying behind the two processes and due to more complete granule rupture caused by higher US power. Evaluating the current results, DOE-based UAE analytical methodology stands out as an auspicious and sustainable alternative for commercial-based extraction of lipidic bioactive compounds for food and drug industrial applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2018.08.010 | DOI Listing |
Sci Rep
January 2025
Department of Electrical Engineering, College of Engineering, King Khalid University, P.O. Box 394, Abha, 61421, KSA, Saudi Arabia.
In wind energy generation systems, ensuring high energy quality is critical but is often compromised due to the limited performance and durability of conventional regulators. To address this, this work presents a novel controller for managing the machine-side inverter of a single-rotor large wind turbine system using an induction machine-type generator. The proposed controller is designed using proportional, integral, and derivative error-based mechanisms, which fundamentally differ from traditional proportional-integral (PI) regulators.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physics, Khalifa University of Science and Technology, 127788, Abu Dhabi, United Arab Emirates.
In this study, biopolymer composites based on chitosan (CS) with enhanced optical properties were functionalized using Manganese metal complexes and black tea solution dyes. The results indicate that CS with Mn-complexes can produce polymer hybrids with high absorption, high refractive index and controlled optical band gaps, with a significant reduction from 6.24 eV to 1.
View Article and Find Full Text PDFTo establish a multivariate linear regression model for predicting the difficulty of high-intensity focused ultrasound (HIFU) ablation of uterine fibroids based on multi-sequence magnetic resonance imaging radiomics features. A retrospective analysis was conducted on 218 patients with uterine fibroids who underwent HIFU treatment, including 178 cases from Yongchuan Hospital of Chongqing Medical University and 40 cases from the Second Affiliated Hospital of Chongqing Medical University (external validation set). Radiomics features were extracted and selected from magnetic resonance images, and potentially related imaging features were collected.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Pharmaceutical Chemistry, Semmelweis University, Hőgyes Endre U. 9, 1092, Budapest, Hungary.
Microtiter-plate-based systems are unified platforms of high-throughput experimentation (HTE). These polymeric devices are used worldwide on a daily basis-mainly in the pharmaceutical industry-for parallel syntheses, reaction optimization, various preclinical studies and high-throughput screening methods. Accordingly, laboratory automation today aims to handle these commercially available multiwell plates, making developments focused on their modifications a priority area of modern applied research.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Physics, Harvard University, Cambridge, MA, USA.
High-resolution fluorescence imaging of ultracold atoms and molecules is paramount to performing quantum simulation and computation in optical lattices and tweezers. Imaging durations in these experiments typically range from a millisecond to a second, significantly limiting the cycle time. In this work, we present fast, 2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!