A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A highly stretchable and conductive 3D porous graphene metal nanocomposite based electrochemical-physiological hybrid biosensor. | LitMetric

A highly stretchable and conductive 3D porous graphene metal nanocomposite based electrochemical-physiological hybrid biosensor.

Biosens Bioelectron

Department of Electronic Engineering, Micro/Nano Devices & packaging Lab., Kwangwoon University, 447-1, Wolgye-Dong, Nowon Gu, Seoul 139-701, Republic of Korea. Electronic address:

Published: November 2018

Recently, highly stretchable and flexible electrodes essential for wearable electronic devices has been reported. However, their electrical resistances are high, the fabrication processes are complicated and involve a high cost, and deformations such as stretching can lead to the degradation on electrical performance. To address these issues, a novel fabrication process (both inexpensive and simple) for the highly stretchable and conductive electrodes using well patterned 3D porous laser-induced graphene silver nanocomposite was developed. The fabricated electrode exhibited a high, uniform electrical conductivity even under mechanical deformations. Addition of platinum and gold nanoparticles (PtAuNP) on the 3D porous LIG greatly improved the electrochemical performance for wearable glucose sensor applications. The fabricated glucose sensor exhibited low detection limit (5 µM), and acceptable detection range from 0 to 1.1 mM (covers the glucose range in sweat), and high linearity (0.99). In addition, the fabricated pH sensor also exhibited a linear response (66 mV/pH) at the range from 4 to 7. This work successfully demonstrates the potential of this novel fabrication technique and stretchable LIG metal nanocomposite for wearable electrochemical-physiological hybrid biosensors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2018.07.071DOI Listing

Publication Analysis

Top Keywords

highly stretchable
12
stretchable conductive
8
metal nanocomposite
8
electrochemical-physiological hybrid
8
novel fabrication
8
glucose sensor
8
sensor exhibited
8
conductive porous
4
porous graphene
4
graphene metal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!