This study was performed to determine if baseline aortic regurgitation (AR) affects the deleterious effects of postprocedure paravalvular leak following transcatheter aortic valve implantation (TAVI). We evaluated the effect of baseline AR on mortality in a large cohort of patients randomized to transcatheter or surgical aortic valve replacement (SAVR). The analysis cohort comprised 739 patients who underwent attempted TAVI (n = 386) or SAVR (n = 353) in the CoreValve US Pivotal High Risk Trial and had baseline AR measurements. Patients were stratified by the severity of baseline AR into those with none and/or trace and those with ≥mild AR. Echocardiographic measurements were assessed by an independent core laboratory. Of the 386 TAVI patients, 204 (52.9%) had none and/or trace at baseline AR; 182 (47.2%) had ≥mild AR. Of the 353 SAVR patients, 169 (47.9%) had none and/or trace and 184 (52.1%) ≥mild AR. The presence of ≥mild baseline AR was associated with lower all-cause mortality at 1 year following TAVI (9.4% vs 18.6%, p = 0.008) or SAVR (13.3% vs 24.4%, p = 0.009). Mortality remained lower in the ≥mild baseline AR patients at 3 years after SAVR (p = 0.011), but not TAVI. In conclusion, baseline AR appears to provide a protective effect on survival and quality of life in both TAVI and SAVR patients at 1 year; this effect persists out to 3 years in SAVR patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2018.07.018 | DOI Listing |
JACC Cardiovasc Interv
December 2024
Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
JACC Cardiovasc Interv
December 2024
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.
Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.
Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.
Am J Med Genet C Semin Med Genet
January 2025
Medical Genetics, Department of Pediatrics, Mass General for Children, Boston, Massachusetts, USA.
Determining karyotype-phenotype correlations for individuals with Turner syndrome ("TS individuals") is a longstanding research endeavor. The limited literature on Turner syndrome (TS) with a ring X chromosome hinders counseling about the neuropsychological and clinical features. To further characterize these phenotypes, we compared 27 TS individuals with 46,X,r(X)/45,X ("ring X") to 50 non-mosaic 45,X, and 27 mosaic 45,X/46,XX ("mosaic 45,X") individuals.
View Article and Find Full Text PDFEur J Clin Invest
January 2025
Department of Cardiology, Bern University Hospital, Inselspital, Bern, Switzerland.
Background: The human microbiome is crucial in regulating intestinal and systemic functions. While its role in cardiovascular disease is better understood, the link between intestinal microbiota and valvular heart diseases (VHD) remains largely unexplored.
Methods: Peer-reviewed studies on human, animal or cell models analysing gut microbiota profiles published up to April 2024 were included.
Turk Kardiyol Dern Ars
January 2025
Department of Cardiology, Gülhane Faculty of Medicine, University of Health Sciences, Ankara, Türkiye.
Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!