  • - JC polyomavirus (JCV) is linked to progressive multifocal leukoencephalopathy (PML), a serious brain disease typically affecting immunosuppressed individuals, making timely diagnosis important for effective treatment.
  • - A new loop-mediated isothermal amplification (LAMP) assay was tested for detecting JCV in cerebrospinal fluid (CSF) and showed impressive specificity and sensitivity, especially when compared to the established qPCR method, analyzing 153 CSF samples.
  • - The results indicated that the LAMP assay reliably quantifies JCV levels in CSF, with high correlation to traditional qPCR results, suggesting it could be a valuable tool for monitoring and managing PML in affected patients.

Article Abstract

Background: JC polyomavirus (JCV) is the causative agent of progressive multifocal leukoencephalopathy (PML), a demyelinating disease of the central nervous system in immunosuppressed patients. PML usually has a poor prognosis. Detection and quantification of the JCV genome in cerebrospinal fluid (CSF) is an efficacious tool for the diagnosis and management of PML, for which proper therapeutic interventions are required.

Methods: A loop-mediated isothermal amplification (LAMP) assay was applied for the quantitative detection of JCV. The LAMP assay was evaluated for the efficacy in diagnosis of PML in comparison with the TaqMan-based quantitative real-time PCR (qPCR) assay using 153 CSF specimens collected from patients with suspected PML.

Results: The LAMP assay showed no cross-reactivity against other polyomavirus plasmids, viral DNA, and viral RNA, which causes encephalitis, and detected 1 copy of the standard DNA per reaction. Among 50 qPCR-positives, 42 specimens (containing JCV genome ranged from 3.2 × 10 to 3.2 × 10 copies/reaction) showed positive reactions and 8 specimens (containing 0.9 to 19.9 copies/reaction) showed negative in the LAMP assay. Furthermore, 3 of 103 qPCR-negative specimens showed positive reactions in the LAMP assay. The sensitivity, specificity, positive predictive value, and negative predictive values of the LAMP assay were 84% (42/50), 97% (100/103), 93% (42/45), and 93% (100/108), respectively. The kappa statistic was 0.83. The JCV loads determined by the LAMP assay showed a strong positive correlation with those determined by the qPCR assay for 33 specimens with copy numbers of ≥1 copies/reaction (r = 0.89). Additionally, the LAMP assay could monitor the JCV genome copy number in CSF for sequential samples equivalently to qPCR assay.

Conclusions: The newly developed LAMP assay is highly specific against JCV and detect the JCV genome in the sample DNA containing 20 or more copies of JCV genome per reaction with 100% sensitivity (n = 29), which corresponds to ≥3 × 10 copies/mL of CSF. The LAMP assay is useful for the diagnosis and offers valuable information for the evaluation and management of PML in the clinical setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6119251PMC
http://dx.doi.org/10.1186/s12985-018-1046-zDOI Listing

Publication Analysis

Top Keywords

lamp assay
40
jcv genome
20
assay
13
lamp
10
jcv
9
loop-mediated isothermal
8
isothermal amplification
8
detection quantification
8
cerebrospinal fluid
8
progressive multifocal
8

Similar Publications

The soybean mosaic disease-caused by the (SMV)-significantly impacts soybean quality and yield. Among its various strains, SMV-SC7 is prevalent in China. Therefore, rapid and accurate diagnosis is deemed critical to mitigate the spread of SMV-SC7.

View Article and Find Full Text PDF

Lab-on-paper for molecular testing with USB-powered isothermal amplification and fluidic control.

Mikrochim Acta

January 2025

Department of Biotechnology and Bioengineering, Chonnam National University, Gwangju, 61186, Republic of Korea.

The global healthcare market increasingly demands affordable molecular diagnostics for field testing. To address this need, we introduce a lab-on-paper (LOP) platform that integrates isothermal amplification with a specially designed paper strip for molecular testing through an automated microfluidics process. The LOP system is engineered for rapid, cost-effective, and highly sensitive detection, using USB-powered thermal management and a wax valve mechanism.

View Article and Find Full Text PDF

Lasiodiplodia theobromae is an emerging threat and the main pathogenic fungi associated with basal stem rot of passion fruit in Guangxi Zhuang Autonomous Region, China. Current pathogen identification protocols are labor-intensive and time-consuming, emphasizing the need for more efficient methods to enable precise surveillance of L. theobromae for early detection and warning.

View Article and Find Full Text PDF

Recent advances in rapid detection of Helicobacter pylori by lateral flow assay.

Arch Microbiol

January 2025

Department of Laboratory Medicine, Jinan Second People's Hospital of Shandong Province (Jinan Eye Hospital), No. 148, Jingyi Road, Jinan, 250022, Shandong, China.

Infection with H. pylori (Helicobacter pylori) is the most prevalent human infection worldwide and is strongly associated with many gastrointestinal disorders, including gastric cancer. Endoscopy is mainly used to diagnose H.

View Article and Find Full Text PDF

Multiplex digital nucleic acid analysis (NAA) allows the precise quantification of multiple target nucleic acids with single-molecule sensitivity, making it highly appealing for life science research and clinical diagnostics. Nucleic acid-guided endonucleases, such as CRISPR, have demonstrated great potential in digital NAA. However, performing multiplex digital NAA with an endonuclease remains challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!