A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of quantitative magnetic resonance imaging metrics in the brain through the use of a novel phantom. | LitMetric

Objective: Multisite and longitudinal neuroimaging studies are important in uncovering trajectories of recovery and neurodegeneration following traumatic brain injury (TBI) and concussion through the use of diffusion tensor imaging (DTI) and other imaging modalities. This study assessed differences in anisotropic diffusion measurement across four scanners using a human and a novel phantom developed in conjunction with the Chronic Effects of Neurotrauma Consortium.

Method: Human scans provided measurement within biological tissue, and the novel physical phantom provided measures of anisotropic intra-tubular diffusion to serve as a model for intra-axonal water diffusion. Intra- and inter-scanner measurement variances were compared, and the impact on effect size was calculated.

Results: Intra-scanner test-retest reliability estimates for fractional anisotropy (FA) demonstrated relative stability over testing intervals. The human tissue and phantom showed similar FA ranges, high linearity and large within-device effect sizes. However, inter-scanner measures of FA indicated substantial differences, some of which exceeded typical DTI effect sizes in mild TBI.

Conclusion: The diffusion phantom may be used to better elucidate inter-scanner variability in DTI-based measurement and provides an opportunity to better calibrate results obtained from scanners used in multisite and longitudinal studies. Novel solutions are being evaluated to understand and potentially overcome these differences.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02699052.2018.1494855DOI Listing

Publication Analysis

Top Keywords

novel phantom
8
multisite longitudinal
8
phantom
5
diffusion
5
assessment quantitative
4
quantitative magnetic
4
magnetic resonance
4
resonance imaging
4
imaging metrics
4
metrics brain
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!