Background: Reliable clinical tests capable of measuring resistance are important tools for rehabilitation. One alternative that has recently increased in popularity is the use of elastic tubes, which stand out for being easy to handle, low cost, practical, and feasible.

Objective: Analyze the test-retest reliability of the knee extensors muscle fatigue resistance test (FRT) with elastic tubes.

Methods: A total of 116 healthy young males, aged between 18 and 30 years old, participated in the study. Participants performed three pre-test stages: orientation, load presentation, and familiarization with equipment, lasting two weeks. Subsequently, they performed the FRT on two occasions (test and retest), with an interval of seven days. The reliability analyzes were performed using the intraclass correlation coefficient (ICC) with 95% confidence interval and typical measurement error (TME), also expressed as coefficient of variation (CV%).

Results: The findings regarding the reliability of the test demonstrated satisfactory values (time: ICC = 0.66; 95%CI [0.50; 0.76]; CV(%) = 9.34; repetition: ICC = 0.61; 95%CI [0.46; 0.73], CV(%) = 13.66; rhythm: ICC = 0.52; 95%CI [0.35; 0.67], CV(%) = 10.29.

Conclusion: From the findings presented, it is concluded that the proposed clinical test with elastic tubes demonstrates evidence of acceptable values.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6118382PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0203259PLOS

Publication Analysis

Top Keywords

test-retest reliability
8
reliability knee
8
knee extensors
8
test elastic
8
elastic tubes
8
test
5
extensors endurance
4
endurance test
4
elastic
4
elastic resistance
4

Similar Publications

Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.

Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.

View Article and Find Full Text PDF

Background: The Minimum Information for Studies Evaluating Biologics in Orthopedics (MIBO) guidelines were developed in May 2017 to encourage improved reporting standards, promote increased transparency and reproducibility, and enhance clinical evaluation capabilities. The MIBO guidelines consist of 23 checklist items considered necessary to critically appraise clinical studies evaluating platelet-rich plasma (PRP).

Purpose: To assess randomized controlled trials that evaluated PRP for the treatment of knee osteoarthritis in order to systematically review their adherence to the MIBO guidelines.

View Article and Find Full Text PDF

One-week test-retest recordings of resting cardiorespiratory data for reliability analysis.

Sci Data

January 2025

Lab for Autonomic Neuroscience, Imaging and Cognition (LANIC), Department of Psychosomatic Medicine and Psychotherapy, Jena University Hospital, Jena, Germany.

Heart rate variability (HRV) is a key indicator of cardiac autonomic function, making reliable assessment crucial. To examine the test-retest stability of resting HRV in healthy individuals, fifty participants attended two lab sessions within a week, at the same time of day. After a 5-minute acclimatization period, electrocardiogram and respiration were recorded at rest.

View Article and Find Full Text PDF

Reliable and sensitive testing of physical function is crucial for assessing the effects of treatment or exercise intervention in various patient populations. The present study investigated the test-retest reliability and sensitivity (smallest detectable difference: SDD) of selected physical performance tests commonly used in clinical rehabilitation, including tests of habitual and maximal walking speed, walking endurance capacity, handgrip strength (HGS), and lower limb muscle power (Sit-to-Stand (STS), stair climb) in adults with severe obesity meeting the criteria for bariatric surgery. Thirty-two adults (BMI 43.

View Article and Find Full Text PDF

Alexithymia, a cognitive and emotional deficit characterized by difficulty in expressing emotions and identifying feelings, poses significant challenges in healthcare settings. Developing a reliable and valid tool to measure alexithymia in post-prostatectomy patients would not only aid healthcare professionals in identifying at-risk individuals but also facilitate early intervention and targeted support. This study aimed to translate the Brief Form of the Normative Male Alexithymia Scale (NMAS-BF) into Simplified Chinese, evaluate the reliability and validity of the Chinese version, and explore its influencing factors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?