In this study, the effectiveness of transthoracic ultrasound elastography in the benign and malign distinction of subpleural/pleural solid lesions was investigated.Between July 2015 and December 2016, 33 consecutive patients with subpleural solid lesions detected via computed tomography (CT) of the thorax were identified and prospectively included in this study. The average for each lesion's shear wave velocity (SWV) value was detected, and benign and malignant lesions' SWV values are statistically compared. The CT and pathology results were used as a reference to compare these values. A receiver operating characteristic analysis was used to determine the cutoff value for benign/malignant neoplasms.The 33 patients (10 female, 23 male) included in the study had a mean age of 56.2 ± 15.40 years (range, 17-84 years), and the mean SWV value of the lesions in 13 (39%) cases evaluated benign after a CT scan, histopathological examination, or both 2.18 ± 0.49 m/s. The mean SWV value of the lesions which were histopathologically diagnosed as malign in 23 (61%) cases was 3.50 ± 0.69 m/s. (P < 0.001). When the cutoff value was set as 2.47 m/s for the SVW value, sensitivity and specificity were determined to be 97.7%.The present study has shown that transthoracic ultrasound shear wave elastography can be an effective radiological examination method in the benign and malign differentiation of subpleural lesions and has the potential for use in the routine clinical application of transthoracic ultrasound elastography, a noninvasive method for evaluating the malignancy potentials of such lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RUQ.0000000000000374DOI Listing

Publication Analysis

Top Keywords

shear wave
12
transthoracic ultrasound
12
wave elastography
8
differentiation subpleural
8
subpleural solid
8
ultrasound elastography
8
benign malign
8
solid lesions
8
included study
8
swv lesions
8

Similar Publications

Elasticity Characteristics of Thenar Muscles in Carpal Tunnel Syndrome.

Ultrasound Med Biol

January 2025

Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA. Electronic address:

Objective: Measurement of thenar muscle elasticity by ultrasound shear wave elastography (SWE) may be useful for the diagnosis and evaluation of carpal tunnel syndrome (CTS), but there is a paucity of information on SWE of the thenar muscles in patients with CTS. The purpose of this study was to investigate the elasticity of the thenar muscles in patients with CTS.

Methods: Twenty-two adult patients with a referral diagnosis of CTS (27 hands) and 20 healthy volunteers as a control (20 dominant hands) participated in this study.

View Article and Find Full Text PDF

Polycystic ovary syndrome (PCOS) is a common endocrine disorder with various contributing factors. Shear wave elastography (SWE) is a contemporary noninvasive imaging technique that reports on the elasticity of tissues. This study aimed to evaluate ovarian stiffness in patients with PCOS using transvaginal SWE, and investigate the potential biological mechanisms underlying increased ovarian stiffness.

View Article and Find Full Text PDF

Objective: To investigate integrating an artificial intelligence (AI) system into diagnostic breast ultrasound (US) for improved performance.

Materials And Methods: Seventy suspicious breast mass lesions (53 malignant and 17 benign) from seventy women who underwent diagnostic breast US complemented with shear wave elastography, US-guided core needle biopsy and verified histopathology were enrolled. Two radiologists, one with 15 years of experience and the other with one year of experience, evaluated the images for breast imaging-reporting and data system (BI-RADS) scoring.

View Article and Find Full Text PDF

Ultrasonic time-of-flight diffraction (TOFD) technique is applied to non-destructive testing in engineering, but the dead zone influences its applicable range. Alternative TOFD techniques adopt the indirect diffracted waves having long propagation times to decouple from the lateral wave and detect near-surface defects. It should be noted that the applicability of these diffracted waves varies with parameter conditions employed for detection, e.

View Article and Find Full Text PDF

Background: To date, no specific treatment has been established to reverse progressive chronic kidney disease (CKD).

Aim: To evaluate the safety and efficacy of autologous CD34 cell transplantation in CKD patients who exhibited a progressive decline in renal function.

Methods: The estimated glomerular filtration rate (eGFR) at the beginning of the study was 15.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!