Aims/hypothesis: Our aim was to quantify the impact of Blood Glucose Monitoring Strips variability (BGMSV) at GP practice level on the variability of reported glycated haemoglobin (HbA1cV) levels.
Methods: Overall GP Practice BGMSV and HbA1cV were calculated from the quantity of main types of BGMS being prescribed combined with the published accuracy, as % results within ±% bands from reference value for the selected strip type. The regression coefficient between the BGMSV and HbA1cV was calculated. To allow for the aggregation of estimated three tests/day over 13 weeks (ie, 300 samples) of actual Blood Glucose (BG) values up to the HbA1c, we multiplied HbA1cV coefficient by √300 to estimate an empirical value for impact of BGMSV on BGV.
Results: Four thousand five hundred and twenty-four practice years with 159 700 T1DM patient years where accuracy data were available for more than 80% of strips prescribed were included, with overall BGMSV 6.5% and HbA1c mean of 66.9 mmol/mol (8.3%) with variability of 13 mmol/mol equal to 19% of the mean. At a GP practice level, BGMSV and HbA1cV as % of mean HbA1c (in other words, the spread of HbA1c) were closely related with a regression coefficient of 0.176, P < 0.001. Thus, greater variability in the BGMS at a GP practice level resulted in a greater spread of HbA1C readings in T1DM patients. Applying this factor for BGMS to the national ISO accepted standard where 95% results must be ≤±15% from reference, revealed that for BG, 95% results would be ≤±45% from the reference value. Thus, the variation in BG is three times that of the BGMS. For a patient with BG target @10 mmol/L using the worst performing ISO standard strips, on 1/20 occasions (average 1/week) actual blood glucose value could be >±4.5 mmol/L from target, compared with the best performing BGMS with BG >±2.2 mmol/L from reference on 1/20 occasions.
Conclusion: Use of more variable/less accurate BGMS is associated both theoretically and in practice with a larger variability in measured BG and HbA1c, with implications for patient confidence in their day-to-day monitoring experience.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6766879 | PMC |
http://dx.doi.org/10.1111/ijcp.13252 | DOI Listing |
J Occup Environ Hyg
January 2025
Human and Environmental Physiology Research Unit, School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, Ontario, Canada.
With mines extending deeper and rising surface temperatures, workers are exposed to hotter environments. This study aimed to characterize heat stress and strain in the Canadian mining industry and evaluate the utility of the Heat Strain Score Index (HSSI), combined with additional self-reported adverse health outcomes. An exploratory web-based survey was conducted among workers ( = 119) in the Canadian mining industry.
View Article and Find Full Text PDFJMIR Public Health Surveill
January 2025
School of Arts and Media, Wuhan College, Wuhan, China.
Background: The global aging population and rapid development of digital technology have made health management among older adults an urgent public health issue. The complexity of online health information often leads to psychological challenges, such as cyberchondria, exacerbating health information avoidance behaviors. These behaviors hinder effective health management; yet, little research examines their mechanisms or intervention strategies.
View Article and Find Full Text PDFJ Med Internet Res
January 2025
Tobacco Settlement Endowment Trust Health Promotion Research Center, Stephenson Cancer Center, University of Oklahoma Health Sciences, Oklahoma City, OK, United States.
Background: Social behavioral research studies have increasingly shifted to remote recruitment and enrollment procedures. This shifting landscape necessitates evolving best practices to help mitigate the negative impacts of deceptive attempts (eg, fake profiles and bots) at enrolling in behavioral research.
Objective: This study aimed to develop and implement robust deception detection procedures during the enrollment period of a remotely conducted randomized controlled trial.
JMIR Res Protoc
January 2025
Cystic Fibrosis Center, Department of Internal Medicine, Hospices Civils de Lyon, Research on Healthcare Performance U1290 Inserm, Lyon 1 University, Lyon, France.
Background: Diabetes affects half of the patients with cystic fibrosis who are aged 30 years and older. Diabetes progresses asymptomatically over a long period of time. Two treatment options are possible: start insulin as soon as cystic fibrosis diagnosis is made with the additional constraints of cystic fibrosis or wait while monitoring the patient's clinical condition and start insulin when diabetes symptoms develop and therefore later.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Guangxi Key Laboratory of Optical and Electronic Material and Devices, School of Materials Science and Engineering, Guilin University of Technology, 12 Jiangan Road, Guilin, Guangxi 541004, China.
Sticker-type transparent antireflective film (STAF) is applied to perovskite solar cells (PSCs) to reduce the reflection and improve the light-trapping ability of PSCs. However, the development of STAF is hindered by many factors, such as expensive materials, low actual service life, unsatisfactory antireflective effect, and a lack of research on stability. This work proposes an ultraviolet (UV)-resistant enhanced sticker-type nanostructure acrylic resin antireflective film (SNAAF), which is applied to the incident surface of PSCs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!