Aims: The aim of this study was to compare the diagnostic performance of superb microvascular imaging (SMI) and power Doppler imaging (PDI) for the differentiation of intraductal breast lesions.

Materials And Methods: A total of 54 intraductal breast lesions (39 benign, 10 atypical, and 5 malignant) in 53 patients were examined using B-mode ultrasonography, PDI, and SMI. Vascularity grading, distribution of microvessels, and penetrating vessels were evaluated using each Doppler technique. The diagnostic performances of both methods were compared.

Results: SMI was more efficient in detecting flow signals than PDI (p=0.004). The highest diagnostic accuracy rates were achieved with SMI using vascular grading. When hypervascularity was used as a cut-off value to differentiate malignant and atypical lesions from benign lesions, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 66.6%, 80.7%, 66.6%, 80.7%, and 75.6%for PDI, and 86.6%, 76.9%, 68.4%, 90.9%, and 80.4% for SMI, respectively.

Conclusions: SMI is more sensitive than PDI for detecting subtle blood flow in intraductal breast lesions with statistical significance. This novel and promising vascular imaging technique may be helpful in B-mode ultrasonography to distinguish intraductal breast lesions.

Download full-text PDF

Source
http://dx.doi.org/10.11152/mu-1433DOI Listing

Publication Analysis

Top Keywords

intraductal breast
16
breast lesions
12
superb microvascular
8
microvascular imaging
8
differentiation intraductal
8
lesions benign
8
666% 807%
8
lesions
6
smi
6
effectiveness superb
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!