A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of Repeated Microwave Disinfection on the Surface Hardness of a Heat-Cured Denture Base Resin: An Study. | LitMetric

Effect of Repeated Microwave Disinfection on the Surface Hardness of a Heat-Cured Denture Base Resin: An Study.

Contemp Clin Dent

Department of Prosthodontics, VSPM DCRC, Nagpur, Maharashtra, India.

Published: January 2018

Statement Of The Problem: Disinfection of complete dentures is very crucial to prevent cross-contamination and infection. Microwave disinfection is a quick, easy, and effective means to disinfect dentures. However, the effect of repeated microwave cycles on the surface hardness property of heat-cured polymethyl methacrylate (PMMA) resin is not known.

Materials And Methods: A total of 60 samples of heat-cured PMMA resin were fabricated for surface hardness. Each group was divided into four groups, according to the number of microwave cycles (MWC) applied for disinfection: control group (no disinfection) 0MWC, 1MWC group, 3MWC group, and 5MWC group.

Results: No significant change on the surface hardness of a heat-cured denture base resin on repeated microwave disinfection.

Conclusion: The repeated microwave disinfection showed statistically nonsignificant change on the surface hardness of the PMMA resin. Microwave disinfection can be safely used in regular practice to avoid cross-contamination and can also be suggested to patients for the regular denture hygiene.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6104382PMC
http://dx.doi.org/10.4103/ccd.ccd_271_18DOI Listing

Publication Analysis

Top Keywords

surface hardness
20
repeated microwave
16
microwave disinfection
16
pmma resin
12
hardness heat-cured
8
heat-cured denture
8
denture base
8
base resin
8
microwave cycles
8
change surface
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!