Evaluation of sample preparation methods for mass spectrometry-based proteomic analysis of barley leaves.

Plant Methods

1Department of Biochemistry and Molecular Biology and VILLUM Center for Bioanalytical Sciences, University of Southern Denmark, Campusvej 55, 5230 Odense M, Denmark.

Published: August 2018

Background: Sample preparation is a critical process for proteomic studies. Many efficient and reproducible sample preparation methods have been developed for mass spectrometry-based proteomic analysis of human and animal tissues or cells, but no attempt has been made to evaluate these protocols for plants. We here present an LC-MS/MS-based proteomics study of barley leaf aimed at optimization of methods to achieve efficient and unbiased trypsin digestion of proteins prior to LC-MS/MS based sequencing and quantification of peptides. We evaluated two spin filter-aided sample preparation protocols using either sodium dodecyl-sulphate or sodium deoxycholate (SDC), and three in-solution digestion (ISD) protocols using SDC or trichloroacetic acid/acetone precipitation.

Results: The proteomics workflow identified and quantified up to 1800 barley proteins based on sequencing of up to 6900 peptides per sample. The two spin filter-based protocols provided a 12-38% higher efficiency than the ISD protocols, including more proteins of low abundance. Among the ISD protocols, a simple one-step reduction and -alkylation method (OP-ISD) was the most efficient for barley leaf sample preparation; it identified and quantified 1500 proteins and displayed higher peptide-to-protein inference ratio and higher average amino acid sequence coverage of proteins. The two spin filter-aided sample preparation protocols are compatible with TMT labelling for quantitative proteomics studies. They exhibited complementary performance as about 30% of the proteins were identified by either one or the other protocol, but also demonstrated a positive bias for membrane proteins when using SDC as detergent.

Conclusions: We provide detailed protocols for efficient plant protein sample preparation for LC-MS/MS-based proteomics studies. Spin filter-based protocols are the most efficient for the preparation of leaf samples for MS-based proteomics. However, a simple protocol provides comparable results although with different peptide digestion profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6109330PMC
http://dx.doi.org/10.1186/s13007-018-0341-4DOI Listing

Publication Analysis

Top Keywords

sample preparation
28
isd protocols
12
protocols
9
preparation
8
preparation methods
8
mass spectrometry-based
8
spectrometry-based proteomic
8
proteomic analysis
8
lc-ms/ms-based proteomics
8
barley leaf
8

Similar Publications

Magnetorheological (MR) fluids can be utilized in one of the fundamental operating modes of which the gradient pinch mode has been the least explored. In this unique mode non-uniform magnetic field distributions are taken advantage of to develop a so-called Venturi-like contraction in MR fluids. By adequately directing magnetic flux the material can be made solidified in the regions near the flow channel wall, thus creating a passage in the middle of the channel for the fluid to pass through.

View Article and Find Full Text PDF

Magnetic supported ionic liquids are a unique subclass of ionic liquids that possess the ability to respond to external magnetic fields, combining the advantageous properties of traditional ILs with this magnetic responsiveness. A novel magnetic ionic nanocatalyst of FeO@SiO@CPTMS-DTPA was prepared by anchoring an ionic liquid, CPTMS-DTPA, onto the surface of silica-modified FeO. The morphology, chemical structure and magnetic property of the magnetic ionic nanocatalyst structure was characterized using scanning electron microscopy, X-ray powder diffraction, Fourier transformation infrared spectroscopy, vibrating sample magnetometer, and thermogravimetric analysis.

View Article and Find Full Text PDF

A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.

View Article and Find Full Text PDF

How to Convert a 3D Printer to Personal Automated Liquid Handler for Life Science Workflows.

SLAS Technol

December 2024

Center for Biomedical Engineering, School of Engineering, Brown University, Providence, RI 02912, USA. Electronic address:

Automated liquid handlers are fundamental in modern life science laboratories, yet their high costs and large footprints often limit accessibility for smaller labs. This study presents an innovative approach to decentralizing a liquid handling system by converting a low-cost 3D printer into a customizable and accurate liquid handler. The Personal Automated Liquid Handler (PALH) system, costing ∼$400, incorporates a single-channel pipet, custom 3D-printed components, and open-source software for personalized workflows, allowing researchers to build and modify the system for specific experimental needs.

View Article and Find Full Text PDF

Ralstonia pickettii bacteremia: a retrospective review of records.

Indian J Med Microbiol

December 2024

Department of Infectious Diseases, Kasturba Medical College, Manipal; Manipal Academy of Higher Education, Manipal 576104. Electronic address:

Introduction: Ralstonia pickettii is a non-fermenting gram-negative bacillus rarely associated with hospital-acquired infections. The study aimed to characterise the clinical profile and outcomes of R. pickettii bacteremia cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!