A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An investigation of laboratory test methods for predicting the in-use leakage performance of urine-absorbing aids in nursing homes. | LitMetric

AI Article Synopsis

  • The study compared two methods for measuring the absorption capacity of urine-absorbing aids: the existing ISO 11948-1:1996 method and a new absorption before leakage method, both evaluated on 12 experimental products and their performance among nursing home residents.
  • The ISO method showed good repeatability and reasonable correlation with real-world data but missed benefits from leg cuffs; the absorption before leakage method, while more complex, had stronger correlations with in-use performance.
  • There's a recommendation to consider the absorption before leakage method as a potential new standard due to its ability to detect performance differences, while other methods tested showed varied effectiveness.

Article Abstract

The absorption before leakage method for measuring the absorption capacity of urine-absorbing aids was investigated. Along with the existing international standard (ISO 11948-1:1996, the Rothwell method), it was run on 12 experimental products whose in-use leakage performance was established by 55 incontinent nursing home residents. Methods were evaluated by considering their simplicity, their repeatability within - and their reproducibility between - six laboratories, and their correlation with in-use product performance. ISO 11948-1:1996 - which measures the absorption capacity of products under simple conditions - showed good repeatability and reproducibility, and reasonable correlation with in-use data. However, it proved blind to the effects of leg cuffs that conferred measurable benefits in real use. It should, therefore, be used with caution. The absorption before leakage method - which measures how much a product will hold before leakage when it is mounted on a manikin and standard aliquots of liquid are applied - is more complex and had poorer repeatability and reproducibility. However, it had stronger correlations with in-use data and successfully detected the benefits of leg cuffs on insert products. It is concluded that it holds potential as a new international standard to replace or complement ISO 11948-1:1996, and the necessary refinement work has been ongoing since the 2007 project described here. Two other laboratory methods were run opportunistically. A rewet method (Spanish national standard UNE 153601-2:2008) - for measuring the escape of fluid from a product under pressure - showed poor repeatability and reproducibility. Finally, an acquisition method was used to measure how quickly products absorbed two successive standard aliquots of liquid. It proved robust, showing good repeatability and reproducibility. Although measurements generally correlated well with in-use leakage performance, a direct causal link is unlikely. Products with high absorption capacity tend also to absorb quickly.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411918792385DOI Listing

Publication Analysis

Top Keywords

repeatability reproducibility
20
in-use leakage
12
leakage performance
12
absorption capacity
12
iso 11948-11996
12
urine-absorbing aids
8
absorption leakage
8
leakage method
8
international standard
8
correlation in-use
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!