In computational fluid dynamics, there is a high interest in modeling flow diverter stents as porous media due to its reduced computational loads. One of the main difficulties of such models is proper parameter setup. Most authors assume flow diverter's wire screen as an isotropic and homogeneous medium, while others proposes anisotropic configurations, yet very little is discussed about the effect of these assumptions on model's accuracy. In this paper, we compare the effect of different models on hemodynamics in relation to their parameters. The fidelity and efficiency of the different models to capture wire screen effect on fluid flow are quantitatively analyzed and compared.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/cnm.3145 | DOI Listing |
World Neurosurg
January 2025
Centre for Computational Imaging and Modelling in Medicine (CIMIM), University of Manchester, Manchester, United Kingdom.
Interv Neuroradiol
January 2025
Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
Introduction: The Flow Re-direction Endoluminal Device (FRED) is a novel flow diverter with a unique double stent design, with an inner stent composed of 48 nitinol wires, and an outer stent with 16 nitinol wires. It is designed for endovascular cerebral aneurysm treatment, although, limited data exist regarding in-stent stenosis (ISS) rates associated with FRED devices.
Methods: A registry encompassing two North American comprehensive stroke centers was the base of this study.
Neurosurg Rev
January 2025
Department of Neurointervention, The First Affiliated Hospital of Zhengzhou University, 450052, Zhengzhou, Henan, China.
To evaluate the safety and efficacy of staged coiling followed by flow diverter (FD) in the treatment of ruptured intracranial aneurysms(RIAs). A retrospective analysis was conducted on 20 patients with RIAs treated with staged coiling followed by FD at a single center, between April 2015 and September 2024. Patient demographics, aneurysm characteristics, clinical and imaging outcomes were reviewed.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.
Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
January 2025
From the Institute of Neurointervention (C. Hecker, C. Hufnagl, A.O., C.J.G., M.K-O.), Paracelsus Medical University, Salzburg, Austria
Background And Purpose: This animal study was designed to evaluate in vivo the acute and short-term safety and efficacy of the new Artisse intrasaccular device (ISD) for aneurysm occlusion and to gain knowledge about the behavior in the aneurysms.
Materials And Methods: The device was implanted in 7 white New Zealand rabbits with bifurcation aneurysms. Immediate and 90-day angiographic follow-up as well as histologic and scanning electron microscope imaging were evaluated.