An Improved Velocity Estimation Method for Wideband Multi-Highlight Target Echoes in Active Sonar Systems.

Sensors (Basel)

Key Laboratory of Underwater Acoustic Signal Processing of Ministry of Education, Southeast University, Nanjing 210096, China.

Published: August 2018

In active sonar systems, the target echoes are usually equivalent to a superposition of the Doppler-scaled reflections from multiple highlights. The reflections overlap with each other both in the time and frequency domain, which results in a decreased velocity estimation performance. Recently, the hyperbolic-frequency modulated signal has been widely employed in sonar systems for moving targets due to its Doppler tolerance, while the precise velocity estimation becomes a great challenge under such conditions. In this paper, the echo c is modeled onsidering a target with a constant velocity and multi-highlights. The velocity estimation performance is analyzed though the signal's matched filter and the wideband ambiguity function. An improved method based on the sliding window matching algorithm is proposed to improve the performance. The method controls the energy of environmental noise and interference by focusing on the dominant target highlight, and applying a designed window which utilizes the Doppler characteristics of hyperbolic-frequency modulated signals. Simulations and lake experiment allow us to compare between the improved method and the conventional matched filter method. The results verify the influence of the multi-highlights in velocity estimation and indicate that the improved method has more effective performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6164034PMC
http://dx.doi.org/10.3390/s18092794DOI Listing

Publication Analysis

Top Keywords

velocity estimation
20
sonar systems
12
improved method
12
target echoes
8
active sonar
8
estimation performance
8
hyperbolic-frequency modulated
8
multi-highlights velocity
8
matched filter
8
method
6

Similar Publications

Objective: The oxidative balance score (OBS) has emerged as a novel marker for assessing oxidative stress status. This study aimed to investigate the association of OBS with systolic blood pressure (SBP), diastolic blood pressure (DBP), all-cause, and cardiovascular disease mortality in hypertensive patients.

Methods: We conducted an analysis of data from 7602 hypertensive patients from the National Health and Nutrition Examination Survey (NHANES) 2005-2018.

View Article and Find Full Text PDF

Introduction: To examine the longitudinal association between estimated pulse wave velocity (ePWV) and cognitive phenotypes in a rural Chinese older population.

Methods: This population-based study included 1857 dementia-free participants (age ≥60 years) who were examined in 2014 and followed in 2018. ePWV was calculated using age and mean blood pressure (MBP).

View Article and Find Full Text PDF

Background: Early menarche is associated with both physical and psychosocial problems. Based on psychological and physical health considerations, for girls with early menarche, some parents and physicians may elect to use gonadotropin-releasing hormone agonists (GnRHa) to delay menstruation. This study aimed to explore the effects of GnRHa treatment on the final height of girls with early menarche and build the models to predict the final adult height (FAH).

View Article and Find Full Text PDF

Comparison of Influence of Office and 24-h Central Aortic Blood Pressure on Target Organ Damage in Hypertension.

J Clin Hypertens (Greenwich)

January 2025

Department of Geriatrics, Medical Center on Aging of Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.

The aim of this study was to explore whether 24-h ambulatory central (aortic) blood pressure (BP) has an advantage over office central aortic BP in screening for hypertension-mediated target organ damage (HMOD). A total of 714 inpatients with primary hypertension and the presence of several cardiovascular risk factors or complications involving clinical HMOD were enrolled. Twenty-four hour central aortic BP was measured by means of a noninvasive automated oscillometric device (Mobil-O-Graph).

View Article and Find Full Text PDF

Background: There are significant discrepancies in the optic nerve sheath diameter (ONSD) reported in the literature. We aimed to determine the ultrasonographic imaging features of ONSD and ophthalmic vessels in a healthy population, using a standardized protocol, and to estimate the effect of demographics and positioning changes on imaging measurements.

Methods: We measured the mean values of the ONSD in supine and sitting position and the Doppler imaging parameters of the ophthalmic, central retinal and short posterior ciliary arteries.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!