Suture pulley countertraction method reduces procedure time and technical demand of endoscopic submucosal dissection among novice endoscopists learning endoscopic submucosal dissection: a prospective randomized ex vivo study.

Gastrointest Endosc

Developmental Endoscopy Lab, Harvard Medical School, Boston, Massachusetts, USA; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Boston, Massachusetts, USA.

Published: January 2019

Background And Aims: The lack of reliable countertraction in endoscopic submucosal dissection (ESD) contributes to its technical demand and increased procedure time. We aimed to prospectively evaluate the efficacy of the suture pulley countertraction method in endoscopists new to both suturing and ESD.

Methods: Two 30-mm circular lesions were created in an ex vivo porcine stomach model. Endoscopists considered novices for both endoscopic suturing and ESD were randomized to either traditional or suture pulley ESD first and performed ESD using each technique. Procedure time was recorded including time of circumferential incision, suture pulley placement, and submucosal dissection. After completion of each ESD, participants graded the difficulty of the procedure using the National Aeronautical and Space Administration (NASA) Task Load Index.

Results: Thirteen participants (8 fellows, 5 attendings) completed the study using both methods. Mean total procedure time was shorter using suture pulley ESD compared with traditional ESD (26.7 ± 7.3 vs 59.4 ± 20.4 minutes, P < .001). The suture pulley required a mean 6.2 ± 2.1 minutes to place. Submucosal dissection time was shorter using suture pulley ESD compared with traditional ESD (8.4 ± 2.9 vs 47.2 ± 16.3 minutes, P < .001). All 7 individual indices and total score on the NASA Task Load Index were significantly improved using the suture pulley ESD method (P < .001).

Conclusions: The suture pulley countertraction method significantly decreases procedure time and technical demand of ESD among endoscopists at all skill levels who are new to ESD. The results of this study have potential implications for ESD training in the United States.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2018.08.032DOI Listing

Publication Analysis

Top Keywords

suture pulley
36
procedure time
20
submucosal dissection
20
pulley esd
16
esd
13
pulley countertraction
12
countertraction method
12
technical demand
12
endoscopic submucosal
12
suture
9

Similar Publications

Objective: To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.

Methods: A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B).

View Article and Find Full Text PDF

Ultrasound-guided trigger thumb release.

Hand Surg Rehabil

January 2025

Orthopedic Surgery Department, CHU Caremeaux, Nîmes, France.

The purpose of this study was to evaluate the results of a novel retrograde ultrasound-guided A1 pulley release technique for the treatment of trigger thumb. We conducted a retrospective, single-center study of 42 patients who underwent ultrasound-guided A1 pulley release for clinically diagnosed trigger thumb between September 2022 and December 2023. All cases were graded according to the Green classification of trigger finger severity.

View Article and Find Full Text PDF

Arthroscopic V-Shaped Double-Pulley Suture-Bridge Repair of Massive Rotator Cuff Tear.

Arthrosc Tech

November 2024

The Second Affiliated Hospital, Department of Joint Surgery, Hengyang Medical School, University of South China, Hengyang, China.

At present, suture bridge is a feasible choice in the treatment of massive rotator cuff tears (MRCTs). However, high tension on the repair site and medial tension during suture tightening and after medial knotting are unavoidable problems in MRCT repair with a suture bridge. Arthroscopic V-shaped double-pulley suture-bridge repair is a pragmatic surgical technique for the repair of MRCTs.

View Article and Find Full Text PDF

A Parachute Suturing Technique for Rotator Cuff Tear.

Arthrosc Tech

November 2024

Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China.

Rotator cuff tear is a common type of injury. For the treatment of rotator cuff tears, arthroscopic surgery is widely used. However, for massive rotator cuff tears, the rate of recurrent tears after arthroscopic surgical repair is higher.

View Article and Find Full Text PDF