A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effectiveness of Lung-RADS in Reducing False-Positive Results in a Diverse, Underserved, Urban Lung Cancer Screening Cohort. | LitMetric

Purpose: The Lung CT Screening Reporting and Data System (Lung-RADS) was created to standardize lung cancer screening CT reporting and recommendations but has not been well validated prospectively in clinical practice. The aim of this study was to determine the effectiveness of lung cancer screening using Lung-RADS in a diverse, underserved, academic clinical screening program, focusing on whether Lung-RADS would successfully reduce the 23.3% false-positive rate found in the National Lung Screening Trial.

Methods: Institutional review board approval was obtained to study the clinical lung cancer screening cohort. Low-dose CT results were prospectively assigned a Lung-RADS or equivalent score. The proportion of examinations in each Lung-RADS category and the corresponding lung cancer rate, subsequent imaging, interventions, mortality, and compliance were tracked. The National Death Index was queried for follow-up losses.

Results: The cohort comprised 1,181 patients with 2,270 person-years of follow-up from December 2012 to December 2016. The mean age was 64 ± 16.2 years, with 51% women, 63% nonwhite, 71% current smokers, 69% overweight and obese, and multiple comorbidities. The Lung-RADS false-positive rate was 10.4% (95% confidence interval, 8.8%-12.3%). Baseline CT results were negative in 87% (n = 1,031): for Lung-RADS 1, the lung cancer rate was 0.2%, and for Lung-RADS 2, the cancer rate was 0.5%. Positive baseline examinations were Lung-RADS 3 in 10% (n = 119), 4a in 1.2% (n = 14), and 4b in 1.5% (n = 18). Corresponding cancer rates were 3.4%, 43%, and 83%, respectively. Lung cancer prevalence was 2.1%. Mortality was 40% in patients with lung cancer versus 2.5% in the remaining cohort (P < .001). Fifty-four percent of patients were overdue for first annual examinations. Eighty-four percent of patients (n = 989) had follow-up verified via electronic records or personal contact, and the remainder had vital status ascertained via the National Death Index.

Conclusions: Lung cancer screening using Lung-RADS was effective in reducing the false-positive rate compared with the National Lung Screening Trial in a diverse and underserved urban population.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacr.2018.07.011DOI Listing

Publication Analysis

Top Keywords

lung cancer
36
cancer screening
20
diverse underserved
12
lung
12
lung screening
12
false-positive rate
12
cancer rate
12
cancer
11
lung-rads
10
screening
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!