A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for determination of parabens in human breast tumor and peripheral adipose tissue. | LitMetric

An efficient method for the determination of eight parabens in human breast tumor (n = 102) and peripheral adipose tissue samples (n = 87) was successfully developed. After a precipitation procedure (acetonitrile-water-15% (w/v) zinc sulfate solution) was applied to finely-chopped tissue samples, ultrasound-assisted dispersive liquid-liquid microextraction was conducted on the sample solution. The extracted parabens were determined by gas chromatography-mass spectrometry. Significant factors influencing extraction efficiency were screened and optimized using Plackett-Burman design and central composite design. The optimized conditions were obtained at 93 μL 1‑decanol, 500 μL methanol, and ultrasound irradiation power 156 W for 44 s. Under the optimum condition, the proposed method showed enrichment factors between 44.9 and 60.5. The detection limits for parabens were between 0.5 and 1.0 ng g. Calibration curves showed good linearity with coefficients of determination higher than 0.993. Relative standard deviations were lower than 11.8%. No significant matrix effects were observed as recoveries from spiked tissue samples ranged between 79.6% and 113.6%. The sample pretreatment procedure and analytical characteristics showed comparable or superior to those of the previously reported methods. Finally, the procedure was successfully employed in real samples and results indicated a wide existence of parabens in the tested tissues. At least one paraben was detected in 98.9% tissues and the levels ranged from 0.5 to 5931.1 ng g, depending on the types of analytes and tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2018.08.004DOI Listing

Publication Analysis

Top Keywords

tissue samples
12
ultrasound-assisted dispersive
8
dispersive liquid-liquid
8
liquid-liquid microextraction
8
gas chromatography-mass
8
chromatography-mass spectrometry
8
determination parabens
8
parabens human
8
human breast
8
breast tumor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!