Background: Range of motion (ROM) of the shoulder is an integral component of assessment of musculoskeletal shoulder impairments. ROM is typically measured using a universal goniometer (UG). The UG has demonstrated good intra and inter-rater reliability for measuring shoulder ROM, although limitations exist. In recent years, alternative measurement devices such as smartphone applications and digital goniometers have been introduced, potentially addressing some of the shortcomings of the UG. Limited research is available on the validity and reliability of these alternative devices, including the laser-guided digital goniometer, in measuring shoulder ROM.Purpose: The purpose of this study was to investigate the intra- and inter-rater reliability and concurrent validity of a laser-guided digital goniometer (HALO) for measuring active shoulder ROM.

Methods: A convenience sample of healthy volunteers was recruited. To be eligible, participants were required to be between 18 and 75 years of age and able to actively move at least one shoulder into 90 ° of glenohumeral abduction. Self-report of previous significant shoulder injury; previous shoulder surgery; current bilateral shoulder pain; current neck or upper back pain; or referred pain into the upper extremity were exclusion criteria. Active shoulder flexion, abduction, internal rotation, and external rotation were measured for each shoulder. Two evaluators measured each motion twice with each device (HALO and the UG) per shoulder. The intra-class correlation coefficient (ICC) for reliability and validity/agreement between devices was calculated using a two-way mixed model with a 95% confidence interval.

Results: Data were analyzed for 75 shoulders from 41 participants (seven participants had only one shoulder evaluated). Intra-rater reliability ICCs are between 0.82 and 0.91 for the HALO, and 0.83 to 0.95 for the UG. Inter-rater reliability for the HALO was 0.89 to 0.98 and for the UG was 0.90 to 0.98. The ICCs for agreement, comparing the HALO digital goniometer to the UG ranged from 0.79 to 0.99.

Conclusion: This study provides evidence that the HALO digital goniometer can be a reliable and valid tool for measuring shoulder ROM in individuals with healthy shoulders. However, the two devices should not be used interchangeably to evaluate a single individual's change over time for any motion.

Level Of Evidence: Diagnostic Study (clinical measurement), Level 2b.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6088125PMC

Publication Analysis

Top Keywords

digital goniometer
20
shoulder
15
halo digital
12
inter-rater reliability
12
measuring shoulder
12
range motion
8
shoulder rom
8
laser-guided digital
8
active shoulder
8
previous shoulder
8

Similar Publications

Objective: This study aimed to investigate the e!ect of arthroscopic Bankart repair (ABR) alone and ABR with an additional remplissage procedure on joint range of motion and functional results in patients with anterior shoulder instability.

Methods: This retrospective study included patients treated 1 year ago with either ABR alone or the ABR additional remplissage procedure. The Bankart lesion was determined by magnetic resonance imaging, and the amount of glenoid bone loss was determined by computed tomography.

View Article and Find Full Text PDF

: Increasing exercise intensity and performance output with superimposed vibration gains interest, especially in high-performance training. However, the additional benefit of vibration in passive stretching exercises and its mechanisms remain unclarified. : Passive stretching with (ST+V) and without (ST) vibration (20 Hz) was performed in male Olympic youth skiing athletes ( = 8, age: 17.

View Article and Find Full Text PDF

Influence of pelvic position on shoulder range of motion.

BMC Musculoskelet Disord

January 2025

Lecturer of Physical Therapy, Basic Science Department, Faculty of Physical Therapy, Suez University, Suez, Egypt.

Background: pelvis and shoulder are deeply integrated. They are connected by myofascial slings. The pelvic and spinal posture affects the position of the scapula and the activity of its muscles and affects acromio-humeral distance and so that affects shoulder movement.

View Article and Find Full Text PDF

Objective:  Recent advances in smartphone applications for measuring range of motion have led to the development of the physio master application by Trinus Laboratory, Navi Mumbai. This app, equipped with a magnetometer and accelerometer, accurately measures the angle between starting and ending device positions. This study aimed to assess the inter-rater and intra-rater reliability, as well as the criterion validity, of the physio master application in measuring cervical range of motion in healthy individuals.

View Article and Find Full Text PDF

Introduction: Current protocols for delivering percussive therapy (PT) using massage guns are heterogeneous creating a need to establish the impact of study design on physiological measures. This cross-over design study aimed to determine the most effective protocol, among the eight protocols examined, on lower body flexibility, and to support the provision of protocol validation for future research.

Method: Recreationally active healthy adults (n = 35) undertook two main protocols; three sessions per week at 2100 rpm or increasing the speed from session-to-session: 1750 to 2100-2400 rpm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!