We have adapted the methodology of Berry et al. (2012) for Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) treatments at a fixed source to imager distance (SID) based on the manufacturer's through-air portal dose image prediction algorithm. In order to fix the SID a correction factor was introduced to account for the change in air gap between patient and imager. Commissioning data, collected with multiple field sizes, solid water thicknesses and air gaps, were acquired at 150 cm SID on the Varian aS1200 EPID. The method was verified using six IMRT and seven VMAT plans on up to three different phantoms. The method's sensitivity and accuracy were investigated by introducing errors. A global 3%/3 mm gamma was used to assess the differences between the predicted and measured portal dose images. The effect of a varying air gap on EPID signal was found to be significant - varying by up to 30% with field size, phantom thickness, and air gap. All IMRT plans passed the 3%/3 mm gamma criteria by more than 95% on the three phantoms. 23 of 24 arcs from the VMAT plans passed the 3%/3 mm gamma criteria by more than 95%. This method was found to be sensitive to a range of potential errors. The presented approach provides fast and accurate in-vivo EPID dosimetry for IMRT and VMAT treatments and can potentially replace many pre-treatment verifications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2018.07.010DOI Listing

Publication Analysis

Top Keywords

imrt vmat
12
portal dose
12
air gap
12
3%/3 mm gamma
12
in-vivo epid
8
epid dosimetry
8
dosimetry imrt
8
vmat treatments
8
vmat plans
8
three phantoms
8

Similar Publications

Optimizing the cumulative cisplatin dose for concurrent chemoradiotherapy beneficiaries among elderly nasopharyngeal carcinoma patients: a real world study.

Sci Rep

December 2024

Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital and Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, 518116, Guangdong, China.

This study aimed to find a safe and effective cumulative cisplatin dose (CCD) for concurrent chemoradiotherapy (CCRT) beneficiaries among elderly nasopharyngeal carcinoma (NPC) patients. A total of 765 elderly (≥ 60 years old) NPC patients treated with cisplatin-based CCRT and IMRT-alone from 2007 to 2018 were included in this study. RPA-generated risk stratification was used to identify CCRT beneficiaries.

View Article and Find Full Text PDF

The National Database of Health Insurance Claims and Specific Health Checkups of Japan (NDB) is a database that stores anonymized information on medical receipts and health checkups in Japan. The NDB Open Data is a publicly accessible summary table of the NDB database. To reveal annual trends and regional disparities in radiotherapy utilization in Japan, we analyzed the NDB Open Data tables for a 9-year period from 2014 to 2022.

View Article and Find Full Text PDF

Purpose: This systematic review aimed to assess the feasibility, safety, and efficacy of using modern external beam radiotherapy (EBRT) techniques, such as intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic body radiotherapy (SBRT) as alternative approaches to brachytherapy (BRT) in adjuvant treatment of endometrial cancer (EC).

Material And Methods: A systematic review was conducted following PRISMA guidelines. The research question was framed using the PICO method, focusing on patients with EC [P] and comparing modern EBRT techniques (IMRT, VMAT, SBRT) [I] vs.

View Article and Find Full Text PDF

Purpose: To explore the effects of personalized oral stents in intensity-modulated radiation therapy (IMRT) treatment.

Methods: Totally 108 patients with nasopharyngeal carcinoma treated with IMRT at Nanjing Gaochun People's Hospital from January 2021 to December 2023 were selected. Using a random number table method, the patients were divided into experimental group (n=54) using personalized oral stents and control group (n=54) using simple mouthpieces.

View Article and Find Full Text PDF

Background: Modern radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), use complex fluence modulation strategies to achieve optimal patient dose distribution. Ensuring their accuracy necessitates rigorous patient-specific quality assurance (PSQA), traditionally done through pretreatment measurements with detector arrays. While effective, these methods are labor-intensive and time-consuming.

View Article and Find Full Text PDF