A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Japanese structure survey of radiation oncology in 2010. | LitMetric

We evaluated the evolving structure of radiation oncology in Japan in terms of equipment, personnel, patient load, and geographic distribution to identify and overcome any existing limitations. From March 2011 to June 2013, the Japanese Society for Radiation Oncology conducted a questionnaire based on the Japanese national structure survey of radiation oncology in 2010. Data were analyzed based on the institutional stratification by the annual number of new patients treated with radiotherapy per institution. The estimated annual numbers of new and total (new plus repeat) patients treated with radiation were 211 000 and 251 000, respectively. Additionally, the estimated cancer incidence was 805 236 cases, with ~26.2% of all newly diagnosed patients being treated with radiation. The types and numbers of treatment devices actually used included linear accelerator (LINAC; n = 829), telecobalt (n = 9), Gamma Knife (n = 46), 60Co remote afterloading system (RALS; n = 28), and 192Ir RALS (n = 131). The LINAC system used dual-energy functions in 586 units, three-dimensional conformal radiotherapy functions in 663, and intensity-modulated radiotherapy (IMRT) functions in 337. There were 564 JASTRO-certified radiation oncologists, 959.2 full-time equivalent (FTE) radiation oncologists, 1841.3 FTE radiotherapy technologists, 131.3 FTE medical physicists, 121.5 FTE radiotherapy quality managers, and 649.6 FTE nurses. The frequency of IMRT use significantly increased during this year. To conclude, although there was a shortage of personnel in 2010, the Japanese structure of radiation oncology has clearly improved in terms of equipment and utility.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6373681PMC
http://dx.doi.org/10.1093/jrr/rry044DOI Listing

Publication Analysis

Top Keywords

radiation oncology
20
patients treated
12
radiation
9
japanese structure
8
structure survey
8
survey radiation
8
oncology 2010
8
structure radiation
8
terms equipment
8
treated radiation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!