The objective of the study is the quantitative analysis of the dose-time dependences of changes occurring in collagen of bladder and rectum after gamma-irradiation using optical methods [nonlinear microscopy in a second harmonic generation (SHG) detection regime and cross-polarization optical coherence tomography (CP OCT)]. For quantitative assessment of the collagen structure, regions of interest on the SHG-images of two-dimensional (2-D) distribution of SHG signal intensity of collagen were chosen in the submucosa. The mean SHG signal intensity and its standard deviation were calculated by ImageJ 1.39p (NIH). For quantitative analysis of CP OCT data, an integral depolarization factor (IDF) was calculated. Quantitative calculation of the SHG signal intensity and the IDF can provide additional information about the processes of the collagen radiation-induced degradation and subsequent remodeling. High positive correlation between the mean SHG signal intensity and the mean IDF of bladder and rectum demonstrates that CP OCT can be used as an "optical biopsy" in the grading of collagen radiation damage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1117/1.JBO.23.9.091417 | DOI Listing |
ACS Omega
December 2024
Institut für Theoretische Physik and Center for Materials Research (LaMa), Justus-Liebig-Universität Gießen, 35392 Gießen, Germany.
The second harmonic generation (SHG) properties of adamantane-based tetraphenyl clusters are predicted from first principles and analyzed on the basis of the involved electronic transitions. In particular, the effect of a tetrel substitution in the cluster core on the nonlinear optical response is investigated. Electronic transitions spatially localized at the substituents are found to be responsible for the optical nonlinearities.
View Article and Find Full Text PDFLasers Surg Med
December 2024
James C Wyant College of Optical Sciences, University of Arizona, Tucson, Arizona, USA.
Objectives: To study the healing response of rat Achilles tendon when lacerated or treated with intense therapeutic ultrasound (ITU) via utilization of multiphoton microscopy (MPM) imaging and histology.
Materials And Methods: The right Achilles tendon of each Sprague Dawley rat within a cohort was partially lacerated. 1 to 2 days post-surgery, each rat received ITU treatment of the Achilles tendon on either the right or left leg.
J Am Chem Soc
December 2024
Department of Chemistry, National University of Singapore, Singapore 117543, Singapore.
Electrically switchable second harmonic generation (SHG) is highly valuable in electro-optic modulators, which can be deployed in data communication and quantum optics. Coupling circular dichroism (CD) with an electrically controlled SHG process is advantageous because it enhances the signal transmission bandwidth and security while enabling multiple modulation modes for optical logic. However, ferroelectrically switchable chiral second-order nonlinearity is rarely reported.
View Article and Find Full Text PDFMicrosc Res Tech
December 2024
Institute of Photonics and Photon-Technology, Northwest University, Xi'an, China.
Nonlinear multimode imaging is a versatile tool to realize complex structural and compositional information of biological samples. In this study, we presented a novel integrated multimode nonlinear optical microscopy system by using an Er3 + -doped femtosecond fiber laser. The system could perform second harmonic generation (SHG), third harmonic generation (THG), and three-photon fluorescence (3PEF) imaging modes simultaneously.
View Article and Find Full Text PDFJ Chem Phys
December 2024
Department of Chemistry, University of Kansas, Lawrence, Kansas 66045, USA.
Generating wavelength-tunable picosecond laser pulses from an ultrafast laser source is essential for femtosecond stimulated Raman scattering (FSRS) measurements. Etalon filters produce narrowband (picosecond) pulses with an asymmetric temporal profile that is ideal for stimulated resonance Raman excitation. However, direct spectral filtering of femtosecond laser pulses is typically limited to the laser's fundamental and harmonic frequencies due to very low transmission of broad bandwidth pulses through an etalon.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!