Quantified Terminal Ileal Motility during MR Enterography as a Biomarker of Crohn Disease Activity: Prospective Multi-Institution Study.

Radiology

From the Centre for Medical Imaging, University College London, Charles Bell House, 43-45 Foley Street, 2nd Floor, London W1W 7TS, England (A.M., A.A.P., J.M., D.P., D.A., G.B., S.A.T.) and Department of Histopathology/Research Pathology, University College London Hospitals/University College London Cancer Institute, Rockefeller Building, 21 University Street, London WC1E 6DE, England (M.R.J.); Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, the Netherlands (C.P., C.E.T.N., J.T., F.V., J.S.); Department of Pathology, UMC Utrecht, Utrecht, the Netherlands (L.A.B.); and Department of Quantitative Imaging, Technical University Delft, Delft, the Netherlands (F.V.).

Published: November 2018

Purpose To evaluate the accuracy of MRI-quantified small bowel motility for Crohn disease activity against endoscopic and histopathologic reference standards. Materials and Methods For this prospective study, 82 participants (median age, 31 years; range, 16 to 70 years; 42 males [median age, 31 years; range, 17 to 70 years] and 40 females [median age, 31 years; range, 16 to 63 years) underwent colonoscopy and MR enterography within 14 days (from October 2011 to March 2014) at two centers. The Crohn disease endoscopic index of severity (CDEIS), histopathologic activity score (endoscopic biopsy acute histologic inflammatory score [EAIS]), and MR index of activity (MaRIA) were scored in the terminal ileum. Terminal ileal motility was quantified by using an image registration based-motility assessment algorithm (hereafter, Motility). Sensitivity and specificity of Motility (˂0.3 arbitrary units) and MaRIA (≥7 and ≥11) for disease activity (CDEIS ≥4 or EAIS ≥1) were compared by using the McNemar test. Receiver operating characteristic curves were constructed and areas under the curve were compared. Motility was correlated with reference standards by using Spearman rank estimates. Results Terminal ileal Motility was negatively correlated with EAIS (r =-0.61; 95% confidence interval [CI]: 0.7, -0.5) and CDEIS (r = -0.59; 95% CI: 0.7, -0.4). With CDEIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥11) (93% vs 78%, respectively; P = .03), but lower specificity (61% vs 81%, respectively; P = .04). With EAIS as the standard of reference, Motility had higher sensitivity than did MaRIA (≥7) (92% vs 75%, respectively; P = .03) but similar specificity (71% vs 74%, respectively; P >.99). The area under the receiver operating characteristic curve for Motility was 0.86 and 0.87 with CDEIS and EAIS as the standard of reference, respectively. Conclusion The terminal ileal Motility score showed good agreement with endoscopic and histopathologic activity in Crohn disease. © RSNA, 2018 Online supplemental material is available for this article.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2018180100DOI Listing

Publication Analysis

Top Keywords

terminal ileal
16
ileal motility
16
crohn disease
16
disease activity
12
age years
12
years range
12
standard reference
12
motility
11
endoscopic histopathologic
8
reference standards
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!