A new type of optical system comprising double-grating and double wave band spectrometers is designed for atmospheric detection. The optical system can bring oxygen A band (758-778 nm) and water vapor absorption band (758-880 nm) on a charge-coupled device (CCD) at the same time for ultrahigh resolution spectrum measurement. Each absorbed band with three observation directions of atmospheric radiation is imaged in different positions of a common CCD. The spectral resolution is less than 0.07 nm in oxygen A band (758-778 nm), and the spectral resolution is less than 0.28 nm in water vapor absorption band (758-880 nm). Three end faces of the optical fiber are on the slit plane for each wave band, and each end face corresponds to an observation angle. The optical fiber core diameter is 600 μm, the slit width is 25 μm, and the slit length is 18.4 mm. The principle of smile correction is analyzed. The smile of the Czerny-Turner double-grating spectrometer can be compensated by using the tilt field lens in front of the focal plane. The design results corroborate that the maximum smile of the double-grating spectrometer is 5 μm and that the approach of correcting smile is effective. The stray light is analyzed, and the approaches of suppressing the stray light are proposed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.57.006823 | DOI Listing |
Sci Rep
December 2024
Condensed Matter Theory Group, School of Studies in Physics, Jiwaji University, Gwalior, 474 011, India.
This study presents a comprehensive investigation into the intrinsic properties of RNiP (where R = Sm, Eu) filled skutterudite, employing the full-potential linearized augmented plane wave method within density functional theory (DFT) simulations using the WIEN2k framework. Structural, phonon stability, mechanical, electronic, magnetic, transport, thermal, and optical properties are thoroughly explored to provide a holistic understanding of these materials. Initially, the structural stability of SmNiP and EuNiP is rigorously evaluated through ground-state energy calculations obtained from structural optimizations, revealing a preference for a stable ferromagnetic phase over competing antiferromagnetic and non-magnetic phases.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Electronics & Communication, University of Allahabad, Prayagraj, UP, India.
In this article an 8-port annular ring-shaped MIMO antenna for 5G and 5G advanced applications is presented. An annular ring on the radiating plane and novel isolator structure on the ground plane are etched over a Rogers RT/Duorid (5870 tm) substrate to achieve high performance antenna for mm wave applications. A systematic study is performed, and an optimized single port antenna (Design-4) is selected among Designs (1-4).
View Article and Find Full Text PDFAdv Mater
December 2024
Shaanxi Key Laboratory of Macromolecular Science and Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an, Shaanxi, 710072, P. R. China.
By manipulating their asymmetric electronic spin states, the unique electronic structures and unsaturated coordination environments of single atoms can be effectively harnessed to control their magnetic properties. In this research, the first investigation is presented into the regulation of magnetic properties through the electronic spin states of single atoms. Magnetic single-atom one-dimensional materials, M-N-C/ZrO (M = Fe, Co, Ni), with varying electronic spin states, are design and synthesize based on the electronic orbital structure model.
View Article and Find Full Text PDFJ Colloid Interface Sci
December 2024
Institute of Corrosion Science and Technology, Guangzhou 510530, China.
With the development of science and technology, there is a great demand for electromagnetic wave absorbing materials for both military and civilian purposes. Among them, carbonyl iron powder (CIP) has attracted a lot of attention due to its mature production system and good electromagnetic wave loss capability. However, the application of CIP is limited due to poor impedance matching, poor corrosion resistance, and poor oxidation resistance.
View Article and Find Full Text PDFVital signs such as heart rate (HR) and respiration rate (RR) are essential physiological parameters that are routinely used to monitor human health and bodily functions. They can be continuously monitored through contact or contactless measurements performed in the home or a hospital. In this study, a contactless Doppler radar W-band sensing system was used for short-range, contactless vital sign estimation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!