Objectives: The aim of this study was to assess the accuracy of detecting and measuring buccal bone thickness (BBT) adjacent to titanium implants in cone beam computed tomography (CBCT) images.
Study Design: Titanium implants (1, 2, or 3), abutments, and metal-ceramic crowns were inserted into 40 bone blocks with various BBTs. CBCT images were acquired in various settings: Voxel sizes (0.2 and 0.13 mm) and reconstruction section thicknesses (2.0 and 5.0 mm) were assessed by 3 examiners. True BBT was measured in digital photographs of the bone blocks. Buccal bone detection was evaluated by sensitivity and specificity. BBT was evaluated by 1-way analysis of variance (ANOVA) between the true and the CBCT measurements and by calculating the difference between the true measurement and the CBCT measurement (Di-BBT).
Results: Detection of buccal bone exhibited high sensitivity (0.86-1) and low specificity (0.14-1). More implants in the field of view, large voxel size, and thick image reconstruction sections had a negative impact on buccal bone detection. ANOVA showed statistically significantly larger BBT for the CBCT measurements in all settings (1.07-1.21 mm) compared with the true measurements (0.85 mm). Di-BBT was mostly within 0.5 mm.
Conclusions: BBT adjacent to titanium implants is overestimated when evaluated on CBCT cross-sectional images.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.oooo.2018.06.004 | DOI Listing |
Oral Maxillofac Surg
January 2025
Department of Dentistry, State University of Maringá (UEM), Maringá, Brazil.
Background: Hybrid Odontogenic Tumors (HOT) are defined by the presence of two or more independent odontogenic tumors that originate from and affect the same maxillofacial site.
Methods: The present study is the first case report of a mandibular HOT consisting of Ameloblastoma, Calcifying Epithelial Odontogenic Tumor, and Ameloblastic Fibroma.
Case Report: A 37-year-old otherwise healthy male presented with the chief complaint of swelling in the right mandibular body.
J Funct Biomater
December 2024
Department and Institute of Oral Surgery, Wroclaw Medical University, Krakowska 26 Street, 50-425 Wrocław, Poland.
Background: The impact of tongue protrusion forces on the formation of malocclusions is well documented in academic literature. In the case of bone dehiscence of the buccal wall in front of the lower frontal teeth, this process may be even more pronounced. Augmentation with 3D customized allogenic bone blocks (CABB) has been proposed as a potential solution for treating such defects.
View Article and Find Full Text PDFDent J (Basel)
January 2025
Department of Oral Surgery, Faculty of Dental Medicine, Medical University of Varna, 9002 Varna, Bulgaria.
Post-extraction ridge resorption is an inevitable phenomenon that cannot be eliminated but is significantly reduced using additional surgical techniques known as socket preservation. They aim to create favorable conditions for implant placement and prosthetic restoration. This study aims to assess the effect of socket sealing (SS) with free gingival grafts on the vertical resorption of socket walls at the premolar and molar regions over 3 months.
View Article and Find Full Text PDFDent J (Basel)
January 2025
Departments of Endodontics, Israel Defense Forces (IDF), Medical Corps, Tel Hashomer Medical Center, Ramat Gan 52621, Israel.
Buccal cortical bone dimensions are crucial in dental radiology, as they impact orthodontic treatment outcomes. Changes in alveolar bone dimensions can result in malocclusion and require interdisciplinary approaches for correction. The accurate quantification of buccal bone dimensions is crucial for appropriate treatment planning and avoiding medico-legal issues.
View Article and Find Full Text PDFKorean J Orthod
January 2025
Department of Orthodontics, Hacettepe University, Ankara, Türkiye.
Objective: This study aimed to evaluate the effects of attachment design on maxillary molar distalization and simultaneous expansion during distalization, and the influence of third molars on distalization in the clear aligner technique using the finite element method.
Methods: Six models were created to evaluate three different attachment designs on the second molars. Model I: employed a vertical rectangular attachment; Model II: used a vertical rectangular attachment with the presence of the third molar; Model III: used a combined semi-elliptical attachment; and Model IV: featured an opposed semi-elliptical attachment with buccal and palatal components.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!