Use of high resolution computed tomography to diagnose ante-mortem dental root fractures in archaeological samples.

Int J Paleopathol

Evolutionary Studies Institute, University of the Witwatersrand, 2050 Johannesburg, South Africa; Molecular Imaging Center, Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; Department of Geology and Palaeontology, Georgian National Museum, 0105 Tbilisi, Georgia.

Published: September 2018

Dental root fractures are rarely documented in past human populations, but when they are observed, diagnosing ante-mortem events as causal factors can be difficult due to postmortem alteration. Can high resolution X-ray computed tomography (CT) improve our ability to diagnose if a dental fracture was caused ante- or post-mortem? To test this, a case study of two individuals with previously diagnosed dental root fractures were re-examined with high resolution CT to confirm or refute the original diagnoses. For individual 4170, use of high resolution CT supported the original diagnosis of an ante-mortem root fracture on the right mandibular central incisor that was made based on planar X-ray. With the new analyses, the root fracture was found to be associated with evidence of calcification, and with radicular and alveolar bone resorption, which are positive correlates of an ante-mortem origin. Resolving this level of detail of bone modification was not possible without using high resolution CT. For individual 4172, the use of high resolution CT enabled visualisation of fracturing and cracking throughout several molars and crowns of other teeth that were not evident in planar X-ray, suggesting that these fractures were likely produced by post-mortem taphonomic processes rather than ante-mortem events as originally diagnosed. In this case study, high resolution CT offered critical advantages compared to a planar X-ray approach, such as using 3D multiple slice views without superimposing alveolar bone and teeth as in planar X-ray imaging. This study demonstrates the potential of high resolution CT in confirming and refuting ante-mortem processes, and that visualisation of 3D structures is crucial for arriving at definitive diagnoses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpp.2017.10.004DOI Listing

Publication Analysis

Top Keywords

high resolution
32
planar x-ray
16
dental root
12
root fractures
12
high
8
computed tomography
8
ante-mortem events
8
case study
8
root fracture
8
alveolar bone
8

Similar Publications

Isolation and identification of two novel PDE-5 inhibitors illegally added to pressed candies.

Food Addit Contam Part A Chem Anal Control Expo Risk Assess

January 2025

Shanxi Key Laboratory of Food and Drug Safety Prevention and Control, Inspection and Testing Center of Shanxi Province, Taiyuan, Shanxi, China.

Two novel phosphodiesterase 5 (PDE-5) inhibitors were detected in pressed candy using high-performance liquid chromatography (HPLC)-diode array detection. Following extraction with acetonitrile and sonication, the compounds were isolated and purified semi-preparative liquid chromatography. Structural characterisation was achieved through high-resolution mass spectrometry (HRMS) and nuclear magnetic resonance (NMR) spectroscopy.

View Article and Find Full Text PDF

Van der Waals electrode integration is a promising strategy to create nearly perfect interfaces between metals and 2D materials, with advantages such as eliminating Fermi-level pinning and reducing contact resistance. However, the lack of a simple, generalizable pick-and-place transfer technology has greatly hampered the wide use of this technique. We demonstrate the pick-and-place transfer of prefabricated electrodes from reusable polished hydrogenated diamond substrates without the use of any sacrificial layers due to the inherent low-energy and dangling-bond-free nature of the hydrogenated diamond surface.

View Article and Find Full Text PDF

Human exposure to mycotoxins is common and often severe in underregulated maize-based food systems. This study explored how monitoring of these systems could help to identify when and where outbreaks occur and inform potential mitigation efforts. Within a maize smallholder system in Kongwa District, Tanzania, we performed two food surveys of mycotoxin contamination at local grain mills, documenting high levels of aflatoxins and fumonisins in maize destined for human consumption.

View Article and Find Full Text PDF

Extracting speech spectrogram of speech signal based on generalized S-transform.

PLoS One

January 2025

College of Computer Science and Technology, Xinjiang University, Urumqi, Xinjiang, China.

In speech signal processing, time-frequency analysis is commonly employed to extract the spectrogram of speech signals. While many algorithms exist to achieve this with high-quality results, they often lack the flexibility to adjust the resolution of the extracted spectrograms. However, applications such as speech recognition and speech separation frequently require spectrograms of varying resolutions.

View Article and Find Full Text PDF

Protocol for the isolation of silk glands from silkworms for snRNA-seq and spatial transcriptomics.

STAR Protoc

January 2025

State Key Laboratory of Resource Insects, College of Sericulture, Textile and Biomass Sciences, Southwest University, Chongqing 400715, China. Electronic address:

The silk glands (SGs) of silkworms specifically synthesize silk proteins, thus strongly influencing the yield and quality of silk. Here, we present a protocol for isolating SG nuclei from silkworms and obtaining high-quality tissue slices for spatial transcriptomics. We describe steps for rearing, dissecting, and nucleus isolation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!