Inhaled iloprost is an effective therapy for patients with pulmonary arterial hypertension (PAH); however, some patients experience extended inhalation times when using the V10 formulation (10.0 µg/mL) to deliver a 5 -µg dose (at mouthpiece) and are at risk of incomplete inhalations and reduced inhalation frequency. VENTASWITCH was an observational, case-crossover study to evaluate inhalation behavior in patients with PAH switched from iloprost V10 to V20 (20.0 µg/mL) formulation for delivering a 5 -µg dose using the I-Neb® AAD® device. Adults with PAH participating in a German Ventavis® (iloprost) patient-support program, who were switched from the V10 to V20 formulation, were enrolled. The co-primary endpoints were mean daily proportion of complete inhalations and mean daily inhalation frequency. The secondary endpoint was mean daily inhalation duration. Data were collected for three months before and after switching. Overall, 63 patients were included. Switching from V10 to V20 resulted in a significant increase in the mean daily proportion of complete inhalations (92% vs. 97%, P < 0.0001) and inhalation frequency (4.6 vs. 4.9 inhalations/day, P = 0.0430), and reduction in mean inhalation duration (11.8 vs. 6.5 min; P < 0.0001). Greater increases in daily proportions of complete inhalations were observed in older patients (≥ 65 vs. < 65 years) and those receiving more (3 vs. < 3) concomitant PAH medications. Switching from V10 to V20 iloprost formulation significantly improved inhalation behavior in patients with PAH and may facilitate improved adherence to therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6128078PMC
http://dx.doi.org/10.1177/2045894018798921DOI Listing

Publication Analysis

Top Keywords

v10 v20
12
inhaled iloprost
8
patients pulmonary
8
pulmonary arterial
8
arterial hypertension
8
5 -µg dose
8
inhalation frequency
8
daily proportion
8
proportion complete
8
complete inhalations
8

Similar Publications

Aim: To characterize the differences of dynamic changes for absolute lymphocyte count (ALC) among esophageal squamous cell carcinoma (ESCC) patients treated with neoadjuvant chemoradiotherapy (nCRT) with or without pembrolizumab, as well as to investigate the clinical and lymphocyte-related organs dosimetric parameters that would impact ALC nadir during nCRT.

Materials And Methods: A total of 216 ESCC patients who received nCRT (with pembrolizumab 144; without pembrolizumab: 72) were identified from a prospective cohort. Weekly and 1-month post-nCRT ALC were identified.

View Article and Find Full Text PDF

Dynamic WaveArc (DWA) is a technique used for continuous, non-coplanar volumetric-modulated arc therapy on the Vero4DRT platform. This study aimed to evaluate the application of single-isocenter DWA (SI-DWA) for treating multiple brain metastases by comparing dose distribution and irradiation time with multi-isocenter DWA (MI-DWA) through retrospective treatment planning. Treatment plans were developed for SI-DWA and MI-DWA in 14 cases with 3-5 brain metastases.

View Article and Find Full Text PDF

Objective: Compared the dosimetric characteristics of half-field-based VMAT and half-field-based IMRT for left breast cancer patients combined with deep inspiration breath-hold (DIBH) and free breathing (FB) techniques.

Methods: Twenty-one left breast cancer patients were included. Each patient underwent DIBH and FB CT scans, IMRT and VMAT plans in half-field beam mode for both breathing techniques, resulting in four plans: FB-IMRT (F-IMRT), FB-VMAT (F-VMAT), DIBH-IMRT (D-IMRT) and DIBH-VMAT (D-VMAT).

View Article and Find Full Text PDF

Background: Radiation-induced lymphopenia (RIL) is closely related to the prognosis of cervical cancer patients and may affect the efficacy of immune checkpoint inhibitors (ICIs). However, the factors influencing RIL are not very clear. In addition to bone marrow (BM) dose-volume, animal studies indicate radiation-induced bowel injury may be a more crucial factor.

View Article and Find Full Text PDF

Reproducibility and stability of voluntary deep inspiration breath hold and free breath in breast radiotherapy based on real-time 3-dimensional optical surface imaging system.

Radiat Oncol

November 2024

Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, No.55, Section 4, South Renmin Road, Chengdu, China.

Background: The aim of this study was to evaluate the inter-fraction reproducibility and intra-fraction stability of breast radiotherapy using voluntary deep-inspiration breath hold (DIBH) and free breathing (FB) based on an optical surface imaging system (OSIS).

Methods: Seventeen patients (510 breath-hold sessions) treated using a field-in-field (FiF) technique and twenty patients (600 breath-free sessions) treated with a volume-modulated arc therapy (VMAT) technique were included in this retrospective study. All the patients were positioned with the guidance of CBCT and OSIS, and also monitored with OSIS throughout the whole treatment session.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!