A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid diagnostic tests relying on antigen detection from stool as an efficient point of care testing strategy for giardiasis and cryptosporidiosis? Evaluation of a new immunochromatographic duplex assay. | LitMetric

Microscopy is the gold standard for the diagnosis of gastrointestinal parasites but is time-consuming and dependent on operator skills. Rapid diagnostic tests represent alternative methods but most evaluations have been conducted on a limited number of samples preventing their implementation in the clinical setting. We evaluated a new CE-IVD marked immunochromatographic assay (Crypto/Giardia K-SeT®, Coris Bioconcept) for the detection of G. intestinalis and Cryptosporidium spp. in 2 phases (retrospective and prospective) on a set of 482 stool samples including rare Cryptosporidium species. Besides G. intestinalis, this test could represent a rapid and reliable alternative to the modified Ziehl-Neelsen staining for the diagnosis of cryptosporidiosis (sensitivity/specificity were 89.2%/99.3% and 86.7%/100% for G. intestinalis and Cryptosporidium resp.), reducing diagnostic delays. Such strategy would also be time-saving by avoiding wet mount microscopy and concentrations steps, being particularly appropriate for laboratories having little expertise in microscopy or not able to implement molecular diagnostic methods.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diagmicrobio.2018.07.012DOI Listing

Publication Analysis

Top Keywords

rapid diagnostic
8
diagnostic tests
8
intestinalis cryptosporidium
8
tests relying
4
relying antigen
4
antigen detection
4
detection stool
4
stool efficient
4
efficient point
4
point care
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!