Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Vascular resistance is known to be one of the determinants of pulsatile flow. This study aimed to investigate whether quantitative 2-dimensional Doppler ultrasound can capture and evaluate the pulsatility within the placental bed vasculature.
Methods: The placental bed vasculature was imaged by directional power Doppler ultrasound. Ten-second cine clips were recorded by using standardized machine settings. A region of interest with a prominent Doppler signal in the uteroplacental interface was analyzed for the percentage of vascularity to generate a time-vascularity waveform. A vascular pulsatility index representing variation over the cardiac cycle was calculated by the ratio of the systolic-diastolic difference in vascularity to the mean vascularity. The acquisitions were repeated with 6 different pulse repetition frequencies (PRFs) and 3 wall motion filter (WMF) settings to evaluate their impact on the Doppler measurements.
Results: Ten sets of cine clips were analyzed for this study. The pulsatile nature of the vascularity was readily apparent in each cine clip. The measured time-vascularity waveforms showed uniform cyclic variation in vascularity over the cardiac cycle, with systolic vascularity significantly higher than diastolic vascularity at each combination of PRF and WMF (P < .05). A gradual increase in the vascular pulsatility index was observed with an increasing PRF or WMF. Normalization of systolic-to-diastolic measurement provided a stable vascular assessment across the range of PRFs.
Conclusions: Doppler cine clips provide a dynamic representation of the placental bed vasculature and a novel analytic approach to quantitatively evaluating the pulsatility of this critical vascular network. Further work is warranted to explore the reproducibility and clinical potential of this approach.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6347511 | PMC |
http://dx.doi.org/10.1002/jum.14720 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!