Objective: To study the survival and patient outcome in a population of UK patients supported by an implantable left ventricular assist device (LVAD) as a bridge to heart transplantation.
Methods: Data on all adult patients (n=342) who received a HeartMate II or HVAD as a first long-term LVAD between January 2007 and 31 December 2013 were extracted from the UK Ventricular Assist Device (VAD) Database in November 2015. Outcomes analysed include survival on a LVAD, time to urgent listing, heart transplantation and complications including those needing a pump exchange.
Results: 112 patients were supported with the Thoratec HeartMate II and 230 were supported with the HeartWare HVAD. Median duration of support was 534 days. During the study period, 81 patients required moving to the UK urgent waiting list for heart transplantation. Of the 342 patients, 85 (24.8%) received a heart transplant, this included 63 on the urgent list. Thirty-day survival was 88.9%, while overall patient survival at 3 years from LVAD implant was 49.6%. 156 patients (46%) died during LVAD support; the most common cause of death on a VAD was a cerebrovascular accident. There was no significant difference between the two devices used in any outcome.
Conclusions: In a population of patients with advanced heart failure, who have a very poor prognosis, support with an implantable LVAD allowed a quarter to receive a heart transplant in a 3-year period. Overall survival of the cohort was about 50%. With improvement in technology and in post-LVAD management, it is likely that outcomes will improve further.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/heartjnl-2018-313355 | DOI Listing |
J Med Syst
January 2025
Department of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Dementia Research Centre, UCL Queen Square Institute of Neurology, London, United Kingdom.
Background: Knowledge of the chemical composition of amyloid plaques and tau tangles at the earlier stages of Alzheimer's disease (AD) pathology is sparse. This is due to limited access to human brain during life and at the earlier stages of AD pathophysiology and technical limitations in quantifying amyloid and tau species at a subcellular level. Understanding the chemical composition of plaques and tangles, how rapidly they grow and what factors drive growth is important for developing and refining therapeutics.
View Article and Find Full Text PDFClin Cardiol
January 2025
Department of Research, Future Forwards Research Institute, Piscataway, New Jersey, USA.
Background: Left ventricular assist devices (LVADs) are utilized as a therapeutic option for patients with end-stage heart failure. While LVAD implantation can enhance survival rates and quality of life, the procedure has its risks, and postoperative complications are common. This review aims to investigate whether there is an association between living in a rural area and the incidence of postoperative complications or hospital readmissions following LVAD implantation, compared to urban LVAD recipients.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
December 2024
Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Boston, MA.
Cardiogenic shock (CS) in acute myocardial infarction (AMI) is a life-threatening syndrome characterized by systemic hypoperfusion that can quickly progress to multiorgan failure and death. Various devices and configurations of mechanical circulatory support (MCS) exist to support patients, each with unique pathophysiological characteristics. The Intra-aortic balloon pump can improve coronary perfusion, decrease afterload, and indirectly augment cardiac output.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!