Objective: The aim of this study was to investigate radiation dose and image quality of coronary computed tomography (CT) angiography (CCTA) for patients with high heart rate variability (HRv) using 16-cm wide-detector CT scanner.
Methods: One hundred sixty-six patients with uncontrolled heart rate underwent CCTA on a 16-cm wide-detector CT system and were divided into 2 groups based on their HRv for analysis: group A (n = 95, HRv ≤10 beats/min [bpm]) and group B (n = 71, HRv >10 bpm). Images in both groups were reconstructed with motion correction algorithm. Subjective and objective image qualities were analyzed.
Results: There were no significant differences in age, body mass index, and heart rate (68.1 ± 11.4 vs 67.6 ± 12.3 bpm) between the 2 groups (P > 0.05). However, group B had significantly higher HRv than group A (33.5 ± 24.4 vs 7.8 ± 1.2 bpm, P < 0.001). All images were acceptable for clinical diagnosis. Compared with group A, image quality scores in group B decreased slightly (4.1 ± 0.5 vs 4.0 ± 0.6). However, the difference was not statistically significant. The mean effective doses were both relatively low at 2.2 ± 1.1 mSv in group A and 2.6 ± 1.4 mSv in group B.
Conclusions: Single-heartbeat free-breathing CCTA can be performed for patients with high HRv using 16-cm wide-detector CT scanner to achieve diagnostic image quality with low radiation dose.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RCT.0000000000000787 | DOI Listing |
Medicine (Baltimore)
September 2022
Department of Radiology, University Hospital Trnava, Trnava, Slovakia.
Aim of the study was to evaluate the effect of high and irregular heart rate on the image quality and on the radiation exposure using a 256-row, 16-cm wide detector computed tomography (CT) system. Between March and December 2019, 349 patients undergoing CT coronary angiography (CTCA) were prospectively enrolled. Patients were divided into 2 study groups; Group 1 included patients with a regular heart rate of ≤70 bpm, while Group 2 included patients with an irregular heart rhythm or heart rate of >70 bpm.
View Article and Find Full Text PDFJ Xray Sci Technol
October 2021
Medical Imaging Centre, Affiliated Hospital of Ankang University (Ankang Central Hospital), Ankang, China.
Objective: To demonstrate the ability of achieving low dose and high-quality head CT images for children with acute head trauma using 100 kVp and adaptive statistical iterative reconstruction (ASIR-V) algorithm in single rotation on a 16 cm wide-detector system.
Materials And Methods: We retrospectively analyzed the CT dose index (CTDI) and image quality of 104 children aged 0-6 years with acute head trauma (1 hour -3 days) in two groups: Group 1(n = 50) on a 256-row CT with single rotation at a reduced-dose of 100 kVp/240 mA and reconstructed using ASIR-V at 70%level; Group 2(n = 54) on a 64-row CT with multiple rotations at a standard dose of 120 kVp/ 180mA and reconstructed using a conventional filtered back-projection (FBP). Both groups used the 0.
Int J Cardiovasc Imaging
July 2021
Diagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, 1678 Dong Fang Road, Shanghai, 200127, People's Republic of China.
The aim of this study is to explore the feasibility of using a non-sedation protocol for the evaluation of neonatal congenital heart disease by using 16-cm wide-detector CT with a low radiation dose. Thirty-four neonates (group 1) were enrolled to undergo cardiac CT without sedation between August 2018 and March 2019. The control group (group 2) comprising 20 inpatient neonates was sedated.
View Article and Find Full Text PDFMinerva Med
June 2022
Department of Radiology, Affiliated Hospital of Shandong Traditional Chinese Medicine University, Jinan, China.
Acad Radiol
December 2021
Departments of Radiology, West China Hospital, Sichuan University, Guoxue Xiang No. 37, Chengdu, Sichuan 610041, China. Electronic address:
Rationale And Objectives: To investigate the feasibility of combining coronary computed tomography (CT) angiography (CCTA) and CTA to evaluate access vessels for transcatheter aortic valve replacement (TAVR) patients in free-breathing and with single contrast medium injection using a 16-cm-wide detector CT.
Materials And Methods: One hundred and twenty-one consecutive patients (73.33 ± 6.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!