Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Uncorrected refractive error is the leading cause of visual impairment worldwide and has significant quality of life and economic implications. Treatment with subjective refraction and custom-made spectacles requires expensive equipment and highly trained personnel. We examine several alternatives.
Methods: Patients were taught to self-refract using two devices: AdSpecs and the I-test Vision Screener. Ready-made spectacles were fit to the self-refraction and visual acuity (VA) was measured. Donated-spectacles were fit to subjective refraction and VA was measured. Self-refraction and donated spectacles spherical equivalent (SE) and VA were compared to subjective refraction SE and VA.
Results: About 57 patients (102 eyes) were enrolled in the study. Patients accurately determined refractive power with self-refraction by both AdSpecs and the I-test (compared to subjective refraction SE, r = 0.97 and r = 0.94, respectively). SE of donated spectacles fit well with self-refraction SE (r = 0.91). There was no significant difference between best-corrected VA by subjective refraction and VA treated by ready-made spectacles fit to self-refraction by either device (analysis of variance (ANOVA), p non-significant). Patients fit with donated spectacles had significantly worse VA than best-corrected VA by subjective refraction (ANOVA, p < 0.01), although 80% improved to >20/40.
Conclusion: Patients accurately self-refract using both devices and ready-made spectacles fit to self-refraction have excellent visual outcomes. Donated spectacles have worse visual outcomes but might be useful in a subset of patients. Ready-made spectacles fit to self-refraction may provide a treatment alternative to uncorrected refractive error.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/09286586.2018.1500615 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!