Single-angle infrared (IR) reflectance spectroscopy is a proven and effective method for determining the complex optical constants n and k of condensed matter. The modern method uses a Fourier transform IR spectrometer to record the quantitative reflectance R(ν) spectra followed by application of the Kramers-Kronig transform (KKT) to obtain the complex optical constants. In order to carry out the KKT, it is essential to measure the reflectance spectra to as high and low a frequency (wavenumber) as possible. Traditionally, the reflectance spectra of solid specimens consist of large (typically>10  mm diameter) polished single-crystal faces free of defects or voids. The requirement of a large polished face, however, is not a realistic expectation for many synthetic, geologic, or rare specimens where the size is usually small and the morphology can vary. In this paper we discuss several improvements and considerations to both the hardware and far-IR measurement protocols that lead to more accurate R(ν) values and thus to more accurate n/k values, especially for small (millimeter-sized) specimens where the R(ν) spectrum is concatenated from multiple independent R(ν) spectra from overlapping hardware/spectral domains. Specifically, the improved hardware and analyses introduced here include the following: (1) providing a set of far-IR calibration standards; (2) custom-designing and manufacturing low reflectivity, stray-light reducing sample masks for small specimens; (3) minimizing stray light interaction between the sample mask, the interferometer Jacquinot stop, and the detector; (4) optimizing the methods to "splice" together the spectra from independent domains; (5) discussing what methods one can use to obtain or calculate the important R(0  cm) value; (6) using a quartic relationship to extrapolate from the measured R data to R(0); and (7) accounting for the limiting effects of diffraction for the spot size at the sample mask and detector for millimeter-sized specimens, especially at the very long wavelengths. These seven considerations are all highly interconnected and are discussed in turn, as well as their strong interdependencies. This paper presents a holistic approach for determining reliable n/k values of millimeter-sized samples using single-angle reflectance in the mid- and far-IR.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.57.006587DOI Listing

Publication Analysis

Top Keywords

optical constants
12
single-angle reflectance
8
reflectance spectroscopy
8
complex optical
8
rν spectra
8
reflectance spectra
8
n/k values
8
millimeter-sized specimens
8
sample mask
8
reflectance
5

Similar Publications

Efficient photocatalytic degradation of bisphenol A on 2D-3D spherically hierarchical structure ZnInS.

Front Chem

January 2025

Institute of Materials Research, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, Guangdong, China.

Bisphenol A (BPA) poses a significant environmental threat due to its widespread use as an industrial chemical and its classification as an environmental endocrine disruptor. The urgent need for effective BPA removal has driven research toward innovative solutions. In this study, we present the synthesis and application of a novel 2D-3D spherically hierarchical ZnInS (ZIS) photocatalyst for the photocatalytic degradation of BPA under visible light for the first time.

View Article and Find Full Text PDF

Rapid acclimatization to baseline stimulation with a multi-canal vestibulocochlear implant.

Eur Arch Otorhinolaryngol

January 2025

Department of Otorhinolaryngology and Head and Neck Surgery, Division of Balance Disorders, School for Mental Health and Neuroscience (MHENS), Maastricht University Medical Centre, Maastricht, The Netherlands.

Purpose: It is hypothesized that a vestibular implant should re-establish baseline activity of the ampullary nerves. Use of a constant baseline stimulation potentially allows encoding of bi-directional head movements, through the addition of signal modulations. Effective stimulation of the vestibular nerves depends on the ability to acclimate to this baseline signal.

View Article and Find Full Text PDF

Nerve growth factor loaded hypotonic eye drops for corneal nerve repair.

J Control Release

January 2025

National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China; Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325000, China; Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325000, China. Electronic address:

Neurotrophic keratopathy is a degenerative disease caused by corneal nerve damage, leading to corneal ulceration. Recombinant human nerve growth factor (rhNGF) was approved for neurotrophic keratitis therapy; however, the excipients of the eye drops are not optimized for its controlled release. To this aim, we introduce the hypotonic hydrogel PF127 as an excipient for rhNGF in eye drops.

View Article and Find Full Text PDF

Purpose: To investigate changes in eye alignment before and after ICL implantation in patients with myopia having corrected distance visual acuity (CDVA) of ≥0.0 logMAR.

Subjects And Methods: The medical records of 1012 patients without eye movement limitation who underwent bilateral ICL implantation were retrospectively reviewed a at the Eye Center of Sanno Hospital in Japan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!