Introduction And Objectives: In Spain, intra-aortic balloon pump (IABP) has been used frequently as a bridge to urgent heart transplant (HT). We sought to analyze the clinical outcomes of this strategy.

Methods: We conducted a case-by-case, retrospective review of clinical records of 281 adult patients listed for urgent HT under IABP support in 16 Spanish institutions from 2010 to 2015. Pre- and post-transplant survival and adverse clinical events were analyzed.

Results: A total of 194 (69%, 95%CI, 63.3-74.4) patients were transplanted and 20 (7.1%, 95%CI, 4.4-10.8) died during a mean period of IABP support of 10.9±9.7 days. IABP support was withdrawn before an organ became available in 32 (11.4%) patients. Thirty-five (12.5%, 95%CI, 8.8-16.9) patients transitioned from IABP to full-support mechanical devices. Mean urgent waiting list time increased from 5.9±6.3 days in 2010 to 15±11.7 days in 2015 (P=.001). Post-transplant survival rates at 30-days, 1-year, and 5-years were 88.1% (95%CI, 85.7-90.5), 76% (95%CI, 72.9-79.1), and 67.8% (95%CI, 63.7-71.9), respectively. The incidence rate of major adverse clinical outcomes-device dysfunction, stroke, bleeding or infection-during IABP support was 26 (95%CI, 20.6-32.4) episodes per 1000 patient-days. The incidence rate of IABP explantation due to complications was 7.2 (95%CI, 4.5-10.8) cases per 1000 patient-days.

Conclusions: In a setting of short waiting list times, IABP can be used to bridge candidates to urgent HT with acceptable postoperative results, but there were significant rates of adverse clinical events during support.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rec.2018.07.003DOI Listing

Publication Analysis

Top Keywords

iabp support
16
adverse clinical
12
intra-aortic balloon
8
balloon pump
8
heart transplant
8
iabp
8
post-transplant survival
8
clinical events
8
95%ci
8
waiting list
8

Similar Publications

C-Reactive Protein Levels and Outcomes in Infarct-Related Cardiogenic Shock: Data from the ECLS-SHOCK Trial.

Eur Heart J Acute Cardiovasc Care

December 2024

Department of Cardiology, Angiology, Hemostaseology and Medical Intensive Care, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.

Background: The impact of systemic inflammation in acute myocardial infarction complicated by cardiogenic shock (AMI-CS) is still a matter of debate. The present ECLS-SHOCK sub-study investigates the association of C-reactive protein (CRP) levels with short-term outcomes in patients with AMI-CS.

Methods: Patients with AMI-CS enrolled in the multicenter, randomized ECLS-SHOCK trial between 2019 and 2022 were included.

View Article and Find Full Text PDF
Article Synopsis
  • Patients awaiting heart transplants often require colonoscopies due to bleeding or screening needs, but there's limited research on the safety of these procedures for individuals on inotropic medications or mechanical circulatory support.
  • A study was conducted from 2015 to 2021 with 92 heart failure patients undergoing colonoscopy while on advanced heart failure therapies, such as inotropes or mechanical devices.
  • Results indicated that the most common reason for colonoscopy was cancer screening, with significant findings including 8% of screening procedures revealing advanced adenomas and 17% of bleeding-related colonoscopies identifying sources needing intervention, but no major complications related to anesthesia were reported.
View Article and Find Full Text PDF

Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study.

Adv Sci (Weinh)

December 2024

Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.

Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.

View Article and Find Full Text PDF

BACKGROUND Human metapneumovirus (hMPV), classified in the Pneumoviridae family, is primarily known for causing lower respiratory tract infections in children, the elderly, and immunocompromised individuals. However, rare instances have shown that hMPV can also affect other systems, such as the cardiovascular system, leading to conditions like myocarditis. CASE REPORT We describe a 68-year-old man with a medical history of diabetes, hypertension, and liver cirrhosis who presented to the Emergency Department (ED) exhibiting symptoms of fever, cough, and dyspnea.

View Article and Find Full Text PDF

Background: Acute myocardial infarction-related cardiogenic shock (AMICS) is a severe complication associated with exceedingly high mortality rates. While mechanical circulatory support (MCS) has emerged as a potential intervention, the evidence base for independent MCS use remains weak. In contrast, systematic reviews of observational studies have revealed significant mortality reduction when a combination of MCS was used: VA-ECMO in conjunction with a left ventricular (LV) unloading device (Impella or IABP).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!