Catheter ablation (CA) is an effective treatment for ventricular arrhythmias (VA), with a potential for complications. The presence of structural heart disease (SHD) is associated with a higher complication rate although there is no data comparing CA of VA between patients with SHD and those without. We aimed to compare trends, morbidity, and mortality associated with real world practice of CA for VA (ventricular tachycardia and premature ventricular contraction) based on the presence of SHD. Using weighted sampling in the National Inpatient Sample database, we collected and compared characteristics and outcomes of patients with or without SHD that underwent CA of VA. Among 34,907 patients that underwent CA for VA (1999-2013), 18,014 (51.6%) had SHD. Major and all complications occurred among 1,135/18,014 (6.3%) and 2139/18,014 (11.9%) patients with SHD respectively compared with 355/16,893 (2.1%) and 739/16,893 (4.4%) for patients without SHD, p < 0.001 for both comparisons. Furthermore, 452/18,014 (2.51%) with SHD died versus 20/16,893 (0.12%) without SHD, p < 0.001. Heart failure was associated with an odds ratio (OR) of 3.09 for major complications (95%CI: 1.53-6.27, p = 0.002) for patients with SHD while coronary artery disease OR for major complications was 2.47 (95%CI: 1.44-4.23, p = 0.001) for patients without SHD. There was a significant increase in major complications over the 15-year study period in patients with SHD, p < 0.001. In conclusion, the presence of SHD during CA for VA increased the complication rate of major and any complications by approximately threefold for both and the hospital mortality by >20-fold compared with patients without SHD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2018.07.001DOI Listing

Publication Analysis

Top Keywords

patients shd
32
major complications
20
shd
14
shd 0001
12
patients
9
catheter ablation
8
ventricular arrhythmias
8
structural heart
8
heart disease
8
complication rate
8

Similar Publications

Introduction: The low incidence of intradialytic hypotension (IDH) in high-volume (HV) hemodiafiltration (HDF) may help in maintaining gut perfusion during treatment. Preservation of gut endothelial integrity would limit or prevent bacterial translocation and subsequent systemic inflammation, which may contribute to the low mortality rate in HV-HDF.

Methods: Forty patients were cross-over randomized to standard (hemodialysis [HD]) (S-HD), cool HD (C-HD), and HDF (low-volume [LV] and HV, convection volume (CV) of 15 L and ≥ 23 L per session, respectively), each for 2 weeks.

View Article and Find Full Text PDF

Background: Sudden cardiac arrest (SCA) risk stratification in patients with mitral valve prolapse (MVP) may be complicated by other potential causes of arrhythmia.

Objectives: We aimed to characterize SCA survivors with isolated (iMVP) and non-isolated MVP (non-iMVP) and to assess their long-term follow-up.

Methods: This ambispective study included 75 patients with MVP who experienced SCA and were treated in our center between 2009-2024.

View Article and Find Full Text PDF

Sepsis is a major cause of morbidity and mortality worldwide. Among the various types of end-organ damage associated with sepsis, hepatic injury is linked to significantly higher mortality rates compared to dysfunction in other organ systems. This study aimed to investigate potential biomarkers of hepatic injury in sepsis patients through a multi-center, case-control approach.

View Article and Find Full Text PDF

Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

J Orthop Surg Res

December 2024

Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.

View Article and Find Full Text PDF

Background: Catheter ablation is the primary treatment option for idiopathic ventricular tachycardia (VT). It plays a key role in acute therapy of electrical storm, treatment of VTs in patients with structural heart disease (SHD), and can reduce VT burden. Here we report on 10-year clinical outcomes following VT ablation from patients enrolled in the prospective German Ablation Registry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!