Risk of Pseudoarthrosis After Spinal Fusion: Analysis From the Healthcare Cost and Utilization Project.

World Neurosurg

Department of Neurological Surgery, Stritch School of Medicine, Loyola University Medical Center, Maywood, Illinois, USA. Electronic address:

Published: December 2018

Background: Pseudoarthrosis after spinal fusion is an important cause of pain, neurologic decline, and reoperation.

Methods: The Healthcare Cost and Utilization Project State Inpatient Databases were queried in New York, California, Florida, and Washington for adult patients who had undergone new spinal fusion from 2009 to 2011. In accordance with the Healthcare Cost and Utilization Project methods series and analysis guidelines, generalized linear mixed effects models were used to estimate the odds of experiencing postoperative pseudoarthrosis as a function of multivariable patient characteristics, comorbidities, and surgical approach.

Results: Of the 107,420 patients who had undergone cervical fusion, 1295 (1.2%) developed pseudoarthrosis requiring reoperation. On multivariable analysis, the risk factors included posterior (odds ratio [OR], 4.47; 95% confidence interval [CI], 3.92-5.10) and combined (OR, 1.77; 95% CI, 1.33-2.36) approaches, fusion of ≥9 vertebrae (OR, 2.54; 95% CI, 1.38-4.68), smoking (OR, 1.19; 95% CI, 1.05-1.34), and long-term steroid use (OR, 1.89; 95% CI, 1.18-3.00). Of the 148,081 patients who underwent thoracic or lumbar fusion, 2665 (1.8%) developed pseudoarthrosis. Posterior (OR, 0.58; 95% CI, 0.51-0.56) and combined (OR, 0.46; 95% CI, 0.40-0.54) approaches resulted in reduced rates. Fusion of 4-8 vertebrae (OR, 1.52; 95% CI, 1.39-1.67), ≥9 vertebrae (OR, 1.87; 95% CI, 1.49-2.34), hypertension (OR, 1.18; 95% CI, 1.09-1.28), sleep apnea (OR, 1.48; 95% CI, 1.26-1.72), smoking (OR, 1.22; 95% CI, 1.12-1.33), and long-term steroid use (OR, 1.53, 95% CI, 1.08-2.18) resulted in increased rates.

Conclusions: These findings strongly associate several diagnoses with the development of pseudoarthrosis. However, further prospective studies are warranted to establish causation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2018.08.026DOI Listing

Publication Analysis

Top Keywords

95%
13
spinal fusion
12
healthcare cost
12
cost utilization
12
utilization project
12
pseudoarthrosis spinal
8
patients undergone
8
developed pseudoarthrosis
8
≥9 vertebrae
8
long-term steroid
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!